Toshiba JKSSS Series Instruction Manual page 15

Medium voltage solid state starter
Table of Contents

Advertisement

Basic Installation and Operation
Guide
Type / Rating
Run Indication
At Speed Indication
Acceleration Adjustments
Dual Ramp Settings
Deceleration Adjustments
Jog Settings
Kick Start Settings
Fault Display
Lockout Display
Up to 60 Events
Motor Load
Current Data
Thermal Data
Start Data
RTD Data
Voltage Metering
Protocol
Signal
Network
Functionality
OLED Readout
Keypad
Status Indicators
Remote Mount Capability
Operating Memory
Factory Default Storage
Customer Settings and Status
Real Time Clock
TOSHIBA
PROGAMMABLE OUTPUTS
Form C (SPDT), Rated 5A, 240Vac max, (1200 VA)
Programmable
Programmable
Programmable Ramp Types: Voltage or Current Ramp (VR or CR)
Starting Torque: 0 - 100% of line voltage (VR) or 0 - 600% of motor FLA (CR)
Ramp Time: 1 to 120 seconds
Current Limit: 200 - 500% (VR or CR)
4 Options: VR1+VR2; VR1+CR2; CR1+CR2; CR1+VR2
Dual Ramp Control: Ramp 1 = Default
Ramp 2 = selectable via dry contact input
Begin Decel Level: 0 - 100% of line voltage
Stop Level: 0 to 1% less than Begin Decel Level
Decel Time: 1 - 60 seconds
Voltage Jog: 5 - 75%
Kick Voltage: 10 - 100%
Kick Time: 0.1 - 2 seconds
Shorted SCR, Phase Loss, Shunt Trip, Phase Imbalance Trip, Overload,
Overtemp, Overcurrent, Short Circuit, Load Loss, Undervoltage or Any Trip
Coast Down Time, Starts Per Hour, Time Between Starts, and Any Lockout
EVENT HISTORY
Data includes cause of event, time, date, voltage, power factor and current for
each phase and ground fault current at time of event
METERING FUNCTIONS
Percent of FLA
A, B, C Phase Current, Avg. Current, Ground Fault (Option)
Remaining thermal register; thermal capacity to start
Avg. Start Time, Avg. Start Current, Measured Capacity to start, time since last
start.
Temperature readings from up to 12 RTDs (6 stator RTDs)
kW, kVAR, PF, kWH
SERIAL COMMUNICATIONS
Modbus RTU
RS-485, RS-422 or RS232
Up to 247 devices per mode
Full operation, status view, and programming via communications port
OPERATOR INTERFACE
Alpha numeric OLED display
8 function keys with tactile feedback
12 LEDs include Power, Run, Alarm, Trip, Aux Relays
Up to 1000 circuit-feet from chassis (Use twisted, shielded wire & power source)
CLOCK and MEMORY
SRAM loaded from EEPROM at initialization
Flash EPROM, field replaceable
Non-volatile EEPROM, no battery backup necessary
Lithium ion battery for clock memory only
JKSSS Series Solid State Soft Starters
2