Rtd Password Level Configuration (Setpoint; System (Setpoint; Calibration And Service (Setpoint - Toshiba JKSSS Series Instruction Manual

Medium voltage solid state starter
Table of Contents

Advertisement

Basic Installation and Operation
Guide
5.1.10 RTD Password Level Configuration (Setpoint Page 10)
Setpoint
Security
Page
Level
Page 10
Level 3
Set Level 2 Password
Password
Password
Set Level 3 Password
5.1.11 RTD Communications Configuration (Setpoint Page 11)
Setpoint
Security
Page
Level
Set Front Baud Rate
Set Modbus Baud Rate
Page 11
Level 3
Modbus Address Number
Communi-
Password
Set Access Code
cations
Set Link Baud Rate
Remote Start/Stop
5.1.12 System (Setpoint Page 12)
Setpoint
Security
Page
Level
Default Display Screen
Metering Data Page #
Metering Data Screen #
Alarms
RTD Failure Alarm
Thermal Register Alarm
Thermal Alarm Delay
Thermal Register Setup Info
Cold Stall Time
Hot Stall Time
Stopped Cool Down Time
Runing Cool Down Time
Relay Measured Cool Rates
Thermal Register Minimum
Motor Design Ambient Temp
Motor Design Run Temperature
Motor Stator Max Temp
I/B Input to Thermal Register
Use Calculated K or Assign
Press Enter to Clr Thermal Register
5.1.13 Calibration and Service (Setpoint Page 13)
Setpoint
Security
Page
Level
Set Date and Time
(DDMMYY:HHMM)
Enter Date (DDMMYYYY)
Enter Time (HH:MM)
Model #
Firmware REV. #
Press Enter to Access Factory
Settings
TOSHIBA
Description
100
1000
Description
9.6 KB/sec
9.6 KB/sec
247
1
38.4 KB/sec
Disabled
Description
1
1
Disabled
90%
10 sec
O/L Class
½ O/L Class
30 Min
15 Min
Disabled
15%
40C
80% Max
INS CLS
Enabled
7
Description
FACTORY SET;
## / ## / ## ## : ##
FACTORY SET;
## / ## / ####
FACTORY SET;
## :##
FACTORY SET;
######
JKSSS Series Solid State Soft Starters
Factory Setting
Default
000 – 999 Three Digits
0000 – 9999 Four Digits
Factory Setting
Default
2.4, 4.8, 9.6, 19.2, 38.4 KB/sec
2.4, 4.8, 9.6, 19.2, 38.4 KB/sec
1 – 247
1 – 999
2.4, 4.8, 9.6, 19.2, 38.4 KB/sec
Enabled or Disabled
Factory Setting
Default
Enter Metering Page (1-4)
Enter Metering Screen
Page 1(1-10)
Page 2 (1-11)
Page 3 (1 - 29)
Page 4 (1 - 6)
Enabled or Disabled
Off, 40-95%
1-20 sec
O/L Class (5-30) or 4-40 second time
delay
½ O/L Class, 4-40 sec
10-300 Min
10-300 Min
Enabled or Disabled
10-50%
10-90C
50-100% of Motor Stator Max Temp
INS CLS, 10-240 C
Enabled or Disabled
1-50, On
Factory Setting
Default
D=1-31, M=1-12, Y=1970-2069
H=00-23, M=0-59
Display Only, Cannot be changed
######
Available to Qualified Factory Personnel
Range
Section
Range
Section
Range
Section
Range
Section
SP10.1
SP10.2
SP11.1
SP11.2
SP11.3
SP11.4
SP11.5
SP11.6
SP12.1
SP12.2
SP12.3
SP12.4
SP13.1
SP13.2
SP13.3
43

Advertisement

Table of Contents
loading

Table of Contents