Installation, Operation and Maintenance Manual
MAC050515 EN Rev. 0
Section 3: Operating Media, Pressures
3.1
Operating Media
1.
2.
NOTE:
On applications where the spring stroke of single acting actuators is pneumatically
operated, the maximum pressure is 6.5 bar/95 psi.
3.
4.
3.2
Operating Temperature Range
Using standard seals and grease the operating temperature range is -20 °C to +100 °C
(-4 °F to +212 °F) as is indicated on the product label. Other medias and temperatures may
be used but consult your local Hytork supplier for confirmation as to suitability.
Operating Media, Pressures and Temperatures
and Temperatures
Use clean, dry, or lubricated air or inert gas.
Maximum pressure: 8 bar/116 psi.
Dew point 10 K below operating temperature.
For subzero applications take appropriate measures.
Section 3: Operating Media, Pressures and Temperatures
November 2022
5