Installation, Operation and Maintenance Manual
MAC050515 EN Rev. 0
Section 6: Solenoid Valves on
It is recommended that on Spring-Return actuators, the Hytork "CATS" solenoid valves are
used. These valves are specially designed to prevent contamination of the internals of the
actuator by dirt from the atmosphere. This increases the working life of the actuator which
reduces down time and maintenance periods (refer to Figure 3).
Figure 3
Solenoid Valves
Spring-Return Actuators
Hytork "CATS" Solenoid Valve
Spring stroke operation
Section 6: Solenoid Valves
Air stroke operation
November 2022
9