Siemens SENTRON VL Series System Manual page 249

Circuit breakers with communication capability - profibus
Hide thumbs Also See for SENTRON VL Series:
Table of Contents

Advertisement

Byte
22
Property byte for DS128.30 (THD of current)
23
Property byte for DS128.32 (voltage
unbalance)
24
Property byte for DS128.34 (undervoltage)
25
Property byte for DS128.36 (overvoltage)
26
Property byte for DS128.41 (current
unbalance)
27
Property byte for DS130.4 (active power in
normal direction)
28
Property byte for DS130.6 (active power in
reverse direction)
29
Property byte for DS130.8 (capacitive power
factor)
30
Property byte for DS130.10 (inductive power
factor)
31
Property byte for DS130.16 (overfrequency)
32
Property byte for DS130.18 (underfrequency)
33
Property byte for DS130.20 (current THD)
34
Property byte for DS130.22 (voltage THD)
35
Property byte for DS130.24 (peak factor)
36
Property byte for DS130.26 (form factor)
37
Property byte for DS130.30 (long-term mean
value for active power)
38
Property byte for DS130.32 (long-term mean
value for apparent power)
39
Property byte for DS130.36 (long-term mean
value for reactive power)
40
Property byte for DS130.38 (reactive power in
normal direction)
41
Property byte for DS130.42 (reactive power in
reverse direction)
42
Property byte for DS130.44 (apparent power)
43
Property byte for DS130.48 (overcurrent)
44
Property byte for DS130.50
(current that flows to ground)
45
Property byte for DS130.52 (overcurrent in
neutral conductor)
46
Property byte for DS130.54 (long-term mean
value for current)
47
Property byte for DS130.59 (phase unbalance
current)
48
Property byte for DS130.62 (undervoltage)
49
Property byte for DS130.65 (phase unbalance
voltage)
50
Property byte for DS130.68 (overvoltage)
3WL/3VL circuit breakers with communication capability - PROFIBUS
System Manual, 03/2011, A5E01051353-02
Description
Data
Source
Source
point
WL
VL
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
ETU
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Meter. fct.
Data library
8.6 Data sets
Format
Length
Scaling
(bits)
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
PB
8
249

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents