5.4.4 Circuit and functional diagram for internal workpiece clamping

Circuit diagram and monitoring/control functions for internal workpiece clamping
proximity switch
Signal output
Jaw end position open
Clamping position
Jaw end position closed
Jaw end position on clamping
force block open
Clamping position
Jaw end position closed
Clamping force block closed
Fig.°7 Circuit diagram for internal workpiece clamping
Circuit diagram and monitoring/control functions for internal
workpiece clamping
The circuit diagram and the functional diagram show the
recommended settings of the proximity switches for monitoring
"End position closed" and "Clamping position reached."
The circuit diagram can also be adjusted for monitoring "Stroke
end position open" and "Missed clamping position." The proximity
switches can also be individually adjusted on the retaining plate.
Circuit diagram proximity switch
03.00 | KSP3-IM, KSP3-LH-IM | TANDEM Clamping Block | en | 1474090