Stove Operation; Starting The Stove; Manual Activation Of The Pellet Loading System; Modifying The Parameters - Jøtul PF 500 Installation, Operation And Maintenance Manual

Hide thumbs Also See for PF 500:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH

10 STOVE OPERATION

10�1 STARTING THE STOVE
Before every ignition, be sure that burning pot is
completely empty and properly positioned in its seat�
To start the stove hold the
The flame icon will start flashing during the ignition stage
until remaining on steady when the stove has started.
Automatic stove ignition: the stove comes with an
automatic device that starts the pellet stove without using
other traditional fire lighters�
When the stove is started the first time, unpleasant odours
or smoke may be generated, caused by evaporation or
drying of certain materials used� This phenomenon will
gradually disappear� The room should be well ventilated
when starting the stove the first few times�
Whenever the firebox door is opened, avoid leaving it open
for a long period of time to prevent the closing sensor from
notifying the door open status through an acoustic alarm�
Before each ignition, make sure that the fire pot is
completely empty and correctly seated�
Avoid lighting the flame manually if the stove's automatic
ignition system is not working correctly�
10�2 MANUAL ACTIVATION OF THE PELLET
LOADING SYSTEM
When you first start up the stove, or if the tank is
completely empty, first load pellets into the tank, then
manually activate the loading system to charge the circuit
with pellets:
a) Use the arrow buttons
and then press
to confirm;
b) Use the
button to select the password
press
to confirm;
c) Use the
button to scroll to and select submenu
then press
to confirm;
d) Enter password
;
"54"
e) Hold down
button to start the manual loading system.
The system remains in service until the button is released or
after a preset time indicated by an acoustic signal;
f) If necessary, repeat the operation of point e) until a few
pellets have fallen into the fire pot;
g) Empty the fire pot at the end of the operation.
You can only run this procedure when the stove is off and
completely cold.
10�3 MODIFYING THE PARAMETERS
The stove operating parameters can be modified as
described.
The values set will be retained until next modified, even
when the stove is switched off or unplugged from the
power supply.
10�4 SWITCHING OFF
To switch the stove off hold the
seconds; the flame icon will switch off.
To start the stove again it's recommended to wait for the
stove to cool down completely.
The stove should only be switched off following the
procedure described above� Never switch the stove off
by unplugging it from the power supply�
10�5 OPERATION WITH ROOM PROBE ON
24
button for several seconds.
to go to the setup menu
and then
"7"
and
[31]
button for a few
THE STOVE
The stove can be switched on/off manually or in
programmed mode.
The stove modulates output according to the room
temperature read by the probe on the stove (that is, the
stove attempts to maintain the desired temperature while
minimising fuel consumption).
If the user has enabled the "Eco-mode" function , the
stove rather than modulating its output, switches off when
reaching the set temperature, and switches on again when
the room temperature falls below the delta set�
The desired room temperature can be set in the
temperature menu
.