Prompt Code
Prompt Name
01-0029
Shut Down
Displayed to prompt the user to confirm the request to shutdown the printer, despite the fact that
Auto Clean is enabled.
Solution 1:
Press OK to Power Off the Printer.
Solution 2:
Press Cancel to close the prompt.
Prompt Code
Prompt Name
01-8001
Valve
Displayed to indicate that a valve has failed the valve test.
Press OK to close the prompt. Inspect valve connection and replace if Valve / Valve cable as needed
Solution 1:
to resolve.
Prompt Code
Prompt Name
01-8002
Power On
Displayed to indicate that the most recent shutdown was due to a power failure.
Solution 1:
Press OK to close the prompt. Check Printhead and clean as necessary.
Prompt Code
Prompt Name
01-8005
Fault
Written to the event log if a unrecoverable error occurs.
Solution 1:
Press OK to close the prompt. Check Printhead and clean as necessary.
Prompt Code
Prompt Name
01-8006
Vacuum Leak
Displayed to indicate that a (suspected) vacuum leak has been detected.
Solution 1:
Ensure that the Makeup Tank level is OK.
Solution 2:
Perform
Prompt Code
Prompt Name
01-8007
InitFailed
Solution 1:
Hardware on Main PCB is damaged. Replace the Main Board.
Prompt Code
Prompt Name
01-8008
InitFailed
Solution 1:
Hardware on Main PCB is damaged. Replace the Main Board.
Prompt Code
Prompt Name
01-8009
InitFailed
Solution 1:
Hardware on Main PCB is damaged. Replace the Main Board.
Prompt Code
Prompt Name
02-0001
NO PROMPT
Reports set point of the Fan in Percentage (30%-100%) to the Event Log.
BestCode Next Series 8 Technical Manual
Prompt Description
"Auto Clean disabled while device is off."
Prompt Description
"A valve is bad, Valve X." (X Indicates the failed Valve).
Prompt Description
"Last shutdown due to loss of power."
Prompt Description
"Panic History: %ls"
Prompt Description
"Vacuum leak detected."
Venturi Testing
procedure. Inspect Makeup Add lines for loose fittings and clogs.
Prompt Description
"Internal File System initialization failed"
Prompt Description
"USB Interface initialization failed"
Prompt Description
"Network Interface initialization failed"
Prompt Description
Fan speed set to %d."