Before each use, look around and underneath the engine for signs of oil or
gasoline leaks.
Place the tiller on a firm level surface and hold the tiller level (i.e. with the
rotary tines and rear wheels set on the ground). Stop the engine before
starting service of the tiller. Servicing the tiller on an unstable surface of the
ground or without stopping the engine can cause injury and/or equipment
damage.
Daily inspection and service of tiller is essential for safe and reliable operation.
Perform the following check before operation.
1. Tiller outside
Check for fuel and engine oil leaks.
Make sure that there are no flammable materials (dust, straw, etc.) near the
engine.
2. Control lever function
Check that the lever operates smoothly.
3. Wiring and cables
Check the insulation of each wire and cable for tears and cuts.
Check if there is any wire or cable pinched by the neighboring parts.
4. Bolts and nuts tightens
Check for looseness in fastened parts. Securely tighten all loose parts.
5. Engine operation
• Start the engine. Check for abnormal sounds. (See pages 22 through 24 for
starting procedure.)
• Check that the engine stops securely by operating the engine switch. (See
pages 35 and 36 for stopping procedure.)
• If you notice any other abnormal symptoms, consult with your authorized
Honda dealer promptly.