Use this manual as a guide to install the ControlLogix™
Multi-Vendor Interface Module. The following table identifies what
this manual contains and where to find specific information.
Topic
Installation Instructions
Publication 1756-IN001A-US-P - May 2000
See Page
3
4
5
6
6
7
9
10
11
12
12
14
14
15
16
16
16
18
19
20

Advertisement

Table of Contents
loading

Summary of Contents for Rockwell Automation Allen-Bradley ControlLogix 1756-MVI

  • Page 1: Table Of Contents

    Installation Instructions ControlLogix Multi-Vendor Interface Module Catalog Number 1756-MVI Use this manual as a guide to install the ControlLogix™ Multi-Vendor Interface Module. The following table identifies what this manual contains and where to find specific information. Topic See Page European Communities (EC) Directive Compliance Preventing Electrostatic Discharge Identify Module Components Prepare the Chassis for Module Installation...
  • Page 2 • We use the following note to call attention to critical information: Identifies information that is critical for successful IMPORTANT application and understanding of the product. Allen-Bradley And ControlLogix are trademarks of Rockwell Automation. Publication 1756-IN001A-US-P - May 2000...
  • Page 3: European Communities (Ec) Directive Compliance

    ControlLogix Multi-Vendor Interface Module European Communities (EC) Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical...
  • Page 4: Preventing Electrostatic Discharge

    ControlLogix Multi-Vendor Interface Module Preventing Electrostatic Discharge The Multi-Vendor Interface module is sensitive to electrostatic discharge. This module is sensitive to electrostatic discharge. ATTENTION Electrostatic discharge can damage integrated circuits or semiconductors if you touch backplane connector pins. Follow these guidelines when you handle the module: Touch a grounded object to discharge static •...
  • Page 5: Identify Module Components

    ControlLogix Multi-Vendor Interface Module Identify Module Components The 1756-MVI module is shipped with the following six components: 1 - 1756-MVI Module • 3 - Serial Adapter Cables • 1 - 1756-MVI Installation Instructions • 1 - CD ROM (1756-MVID only) •...
  • Page 6: Prepare The Chassis For Module Installation

    ControlLogix Multi-Vendor Interface Module Prepare the Chassis for Module Installation Before you install the MVI module, you must install and connect a ControlLogix chassis (1756-A4, 1756-A7, 1756-A10, or 1756-A13) and power supply (1756-PA72 or 1756-PB72). To install these products, refer to publications 1756-5.1 and 1756-5.2. chassis Power 1756-A4...
  • Page 7: Set The Configuration Jumpers

    ControlLogix Multi-Vendor Interface Module Set the Configuration Jumpers Before installing the 1756-MVI module in the chassis, set the module’s configuration jumpers on the module’s printed circuit board. 1. The module ships with the Setup jumper in the Setup position (see the figure on the following page). The Setup jumper causes the module to boot with console port PRT1 enabled at 19200 baud, no parity, 8 data bits and 1 stop bit.
  • Page 8 ControlLogix Multi-Vendor Interface Module The configuration jumper positions are shown in the following figure. SETUP PRT2 PRT3 RS485 RS232 IN = SETUP MODE RS422 RS422 OUT = APPLICTION RS232 RS485 MODE Publication 1756-IN001A-US-P - May 2000...
  • Page 9: Determine Module Slot Location

    ControlLogix Multi-Vendor Interface Module Determine Module Slot Location You can install the module in any slot in the ControlLogix chassis. You can also install multiple MVI modules in the same chassis. The figure below shows chassis slot numbering in a 4-slot chassis. Slot 0 is the first slot and is always the leftmost slot in the rack (the first slot to the right of the power supply).
  • Page 10: Install The Module In The Chassis

    ControlLogix Multi-Vendor Interface Module Install the Module in the Chassis Align the circuit board with top and bottom guides in the chassis. Circuit Board Slide the module into the chassis. Make sure the module backplane connector properly connects to the chassis backplane.
  • Page 11: Remove Or Replace The Module (When Applicable)

    ControlLogix Multi-Vendor Interface Module Remove or Replace the Module (when applicable) Push on upper and lower module tabs to disengage them. Slide module out of chassis. If you are replacing an existing module with an IMPORTANT identical one, and you want to resume identical system operation, you must install the new module in the same slot.
  • Page 12: Installing Or Removing The Module While Power Is Applied

    ControlLogix Multi-Vendor Interface Module Installing or Removing the Module While Power Is Applied You can install or remove the module while chassis power is applied. When you insert or remove a module while ATTENTION backplane power is on, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: sending an erroneous signal to your system’s...
  • Page 13 ControlLogix Multi-Vendor Interface Module Refer to the following tables to identify the signals on each of the 1756-MVI module’s ports. PRT1 Signals DB-9M Pin RS-232 Signal COM/GND Metal Shell Shield The cable length for PRT1 must not exceed ten (10) IMPORTANT feet.
  • Page 14: Apply Chassis Power

    ControlLogix Multi-Vendor Interface Module Apply Chassis Power Check Power Supply and Module Status Module OK Status Indicator is green Power Supply Indicator is green Publication 1756-IN001A-US-P - May 2000...
  • Page 15: Reading The Status Indicators

    ControlLogix Multi-Vendor Interface Module Reading the Status Indicators LED Identification Description Status Meaning P1, P2, P3 Port Activity No serial activity detected on corresponding port. Green Serial activity detected on corresponding port. U1, U2 User Defined Application dependent BATT Battery Battery voltage normal.
  • Page 16: Perform A Quick Start

    ControlLogix Multi-Vendor Interface Module Perform a Quick Start This section provides a quick overview of the steps necessary to configure the 1756-MVI module. Note that this information is not meant to be More comprehensive. For more detail, refer to the 1756-MVI Programming Reference Manual, publication 1756-RM004A-EN-P.
  • Page 17 ControlLogix Multi-Vendor Interface Module You will see the BIOS Setup Main Menu: System Bios Setup - Utility v4.001 | (C) 1998 General Software, Inc. All rights reserved +---------------------------------------------------------+ MVI Module Configuration Begin Flash ROM Update Mode Reset Configuration to Factory Default Exit +---------------------------------------------------------+ <Esc>...
  • Page 18: Test The Module

    ControlLogix Multi-Vendor Interface Module The configuration set with the MVI Module IMPORTANT Configuration Menu is enabled only when the Setup jumper is not installed. If the Setup jumper is installed, the MVI console port is configured at 19200 baud, no parity, 8 data bits, and 1 stop bit.
  • Page 19: Specifications

    ControlLogix Multi-Vendor Interface Module Specifications Type Specifications Module Location Any slot in the ControlLogix chassis Maximum Backplane Current Load 800mA @ 5.1V DC 3mA @ 24V DC from I/O chassis to ground Power Dissipation Environmental Conditions: Operating Temperature 0 to 60° C (32 to 140° F) Storage Temperature -40 to 85°...
  • Page 20: Cul Hazardous Location Approval

    ControlLogix Multi-Vendor Interface Module CUL Hazardous Location Approval CUL certifies products for general use as well as for use in hazardous locations. Actual CUL certification is indicated by the product label as shown below, and not by statements in any user documentation. CL I, DIV 2 Example of the CUL certification product label: GP A,B,C,D...
  • Page 21 ControlLogix Multi-Vendor Interface Module Approbation d’utilisation dans des environnements dangereux par la CUL La CUL certifie des produits pour une utilisation générale aussi bien que pour une utilisation en environnements dangereux. La certification CUL en vigueur est indiquée par l'étiquette produit et non par des indications dans la documentation utilisateur.