Chapter 4 – Setup and Operation
Chapter 4 covers the firmware and software settings used to prepare the module controller for calibration and
operation. The Setup procedures require Allen Bradley's RS Logix 5000, Allen-Bradley RSLinx™ or RSLinx™ Lite.

Power Check

To make or change settings, there must be power to both the PLC and the module. Verify that the LED's are lit for
normal operation. (See Figure Below)

Setting Up Communications between the PLC and HI 1734-WS

Follow these steps to set up communication between the ControlLogix PLC and the Weigh Scale Module. The steps
require that you have a new or open RS Logix® 5000 project. For instructions, see your RS LOGIX 5000 manual.
When not plugged directly into certain compatible controllers, the HI 1734 WS point I/O module requires a
communications adapter module. For this setup example/instructions, use the A-B 1734-AENT module.
In the program Controller Organizer, find the I/O Configuration Section.
Page | 19
LED Light
Status
Solid Green
Normal (Running)
Flashing Green
Device on standby (needs commissioning)
Solid Red
Unrecoverable Fault
Flashing Red
Minor Fault
Flashing Red/Green
Device Self testing
Dark - Off
No power to the module
LED Light
Status
solid Green
On-line, connected
Flashing Green
On-line, not connected
Solid Red
Critical Link Failure
Flashing Red
Connection time-out
Flashing Red/Green
A specific communication faulted device
Dark - Off
Not Powered/Not Online
LED Light
Status
Steady Green
Running (Normal)
Flashing Green
Error No Calibration
Steady Red
Error Read Failure or Error Eeprom Write
Flashing Red
Read Convert Error
Hardy 1734-WS Installation & Operation Manual
Module Status
Network Status
Scale Status