OVERVIEW OF THE PROCESS IMAGES
Table 4: Safety-related PROFIsafe process image: input of the device, output of the control
Byte
Bit 7
Bit 6
0
Reserved
1
SetMonitoringCaseNoTable1
2
Reserved
3
TriggerReset‐
TriggerReset‐
1)
CutOff‐
CutOff‐
Path08
Path07
4
Reserved
5
Reserved
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
Table 5: Safety-related PROFIsafe process image: output of the device, input of the control
Byte
Bit 7
Bit 6
0
Reserved
1
SafeCutOff‐
SafeCutOff‐
1)
Path08
Path07
2
1)
NonsafeCu‐
NonsafeCu‐
tOffPath08
tOffPath07
3
ResetRequir‐
ResetRequir‐
1)
edCutOff‐
edCutOff‐
Path08
Path07
4
CurrentMonitoringCaseNoTable1
5
Reserved
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
Table 6: Non-safety-related PROFINET process image: output of the device, input of the control
Byte
Bit 7
Bit 6
0
Reserved
1
StatusSafe‐
StatusSafe‐
1)
CutOff‐
CutOff‐
Path08
Path07
2
1)
NonsafeCu‐
NonsafeCu‐
tOffPath08
tOffPath07
3
ResetRequir‐
ResetRequir‐
1)
edCutOff‐
edCutOff‐
Path08
Path07
4
CurrentMonitoringCaseNoTable1
5
Reserved
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
14
T E C H N I C A L I N F O R M A T I O N | microScan3 - PROFINET
Structure of the process image (6 bytes)
Bit 5
Bit 4
TriggerReset‐
TriggerReset‐
CutOff‐
CutOff‐
Path06
Path05
Bit 5
Bit 4
Manipula‐
Reference‐
tionStatus
ContourSta‐
tus
SafeCutOff‐
SafeCutOff‐
Path06
Path05
NonsafeCu‐
NonsafeCu‐
tOffPath06
tOffPath05
ResetRequir‐
ResetRequir‐
edCutOff‐
edCutOff‐
Path06
Path05
Bit 5
Bit 4
Manipula‐
Reference‐
tionStatus
ContourSta‐
tus
StatusSafe‐
StatusSafe‐
CutOff‐
CutOff‐
Path06
Path05
NonsafeCu‐
NonsafeCu‐
tOffPath06
tOffPath05
ResetRequir‐
ResetRequir‐
edCutOff‐
edCutOff‐
Path06
Path05
Bit 3
Bit 2
ActivateS‐
StopAlarm‐
tandbyMode
Detection
TriggerReset‐
TriggerReset‐
CutOff‐
CutOff‐
Path04
Path03
Bit 3
Bit 2
Contamina‐
Contamina‐
tionError
tionWarning
SafeCutOff‐
SafeCutOff‐
Path04
Path03
NonsafeCu‐
NonsafeCu‐
tOffPath04
tOffPath03
ResetRequir‐
ResetRequir‐
edCutOff‐
edCutOff‐
Path04
Path03
Bit 3
Bit 2
Contamina‐
Contamina‐
tionError
tionWarning
StatusSafe‐
StatusSafe‐
CutOff‐
CutOff‐
Path04
Path03
NonsafeCu‐
NonsafeCu‐
tOffPath04
tOffPath03
ResetRequir‐
ResetRequir‐
edCutOff‐
edCutOff‐
Path04
Path03
Bit 1
Bit 0
Reserved
TriggerRun‐
Mode
TriggerReset‐
TriggerReset‐
CutOff‐
CutOff‐
Path02
Path01
TriggerDevi‐
TriggerDevi‐
ceReboot‐
ceRebootWi‐
WithNetwork
thoutNet‐
work
Bit 1
Bit 0
Standbymo‐
RunModeac‐
deActive
tive
SafeCutOff‐
SafeCutOff‐
Path02
Path01
NonsafeCu‐
NonsafeCu‐
tOffPath02
tOffPath01
ResetRequir‐
ResetRequir‐
edCutOff‐
edCutOff‐
Path02
Path01
DeviceError
Applicatio‐
nError
Bit 1
Bit 0
Standbymo‐
RunModeac‐
deActive
tive
StatusSafe‐
StatusSafe‐
CutOff‐
CutOff‐
Path02
Path01
NonsafeCu‐
NonsafeCu‐
tOffPath02
tOffPath01
ResetRequir‐
ResetRequir‐
edCutOff‐
edCutOff‐
Path02
Path01
DeviceError
Applicatio‐
nError
8026545/2021-03-15 | SICK