Refrigeration pressure data

Air-Cooled ice machine capacity/24hrs
Ambient Air Temperature F/C
F
60
70
C
16
21
50
418
388
10
189
176
60
395
370
16
179
168
70
372
353
21
169
160
80
362
340
27
164
154
90
352
327
32
160
148

Compressor data

Air-cooled
Ambient air temperature
Amperage
High-side pressure (PSIG)
Low-side pressure (PSIG)
Locked rotor amps:
Gearmotor data
Gearmotor data
Gearmotor current

Refrigeration system

Caution: Risk of fire.
Important: All service on refrigeration system must be performed in accordance with all federal, state and
local laws that pertain to the use of refrigerants. It is the responsibility of the technician to ensure that these
requirements are met.
R414 ice machine charge specifications
Model
E12CI414A (air-cooled)
4
E12CI414A R290, 230 V 50 Hz
80
90
100
27
32
38
357
325
294
lbs.
162
147
179
kg.
345
313
281
lbs.
156
142
127
kg.
334
301
268
lbs.
151
137
122
kg.
318
288
259
lbs.
144
131
117
kg.
302
275
249
lbs.
137
125
113
kg.
50 F/10 C
230 V
2.2
112
18.5
230 V: 18.2A
230 V/50 Hz
1.3A (nominal)
3.52 oz (100 grams)
70 F/21.1 C
90 F/32.2 C
230 V
230 V
2.3
152
202
21
Charge
110 F/43.3C
230 V
2.5
2.6
260
25
30
Refrigerant type
R290