Specifications; Water; Clearances; Electrical - Follett Chewblet 7 Series Installation, Operation And Service Manual

Countertop and freestanding ice and water dispenser
Hide thumbs Also See for Chewblet 7 Series:
Table of Contents

Advertisement

Specifications

Water

WARNING!
Connect to potable water supply only.
§ Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§ Not recommended for use with softened water
§ Ingress Protection (IP) rating: IPX0 (no protection)

Clearances

§ 7.62 cm (3") behind and on each side of dispenser for electrical and connection and ventilation

Electrical

§ E Series: 230 V, 50 Hz, 1 phase, 5A, maximum fuse 10A
§ C Series: 220 V, 60 Hz, 1 phase, 5A, maximum fuse 10A
§ Connect to dedicated 10A circuit, fuse or breaker.
§ Must be grounded - requires 3-prong outlet. Do not remove ground.
§ Replacement cord instructions, type IEC 60320-C13 attachment - If the supply cord is damaged, it must be
replaced by a special cord or assembly available from the manufacturer or its service agent.

Refrigeration

WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§ Refrigerant R134a – 204 grams (7.2 ounces)

Heat Rejection

§ 498 W (1700 BTU/hr)
Dispenser and Ice Machine 230 V/50 Hz and 220 V/60 Hz
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chewblet 15 seriesChewblet e seriesChewblet c seriesChewblet 15ci100a seriesChewblet 15fs100a series7ci100a series ... Show all