Align the cable entry
Special mounting
instructions
Ambient temperature range
24
1.
2.
26
Housing with external locking screw
Support the device
NOTICE
If the device is supported incorrectly, shocks and vibrations can damage the coated surface.
‣
Only use suitable supports.
Support the device in the event of severe dynamic load. Maximum lateral loading capacity of the pipe
extensions and sensors: 75 Nm (55 lbf ft).
27
Examples of support in the event of dynamic load
Environment
–40 to +70 °C (–40 to +158 °F)
WARNING
L
Permitted connection voltage exceeded!
‣
For electrical safety reasons, the maximum connection voltage for all electronic inserts at
ambient temperatures below –40 °C (–40 °F) is limited to a maximum of 35 V DC.
Liquiphant FTL64
3.
4 0.7 Nm
Endress+Hauser
A0042355
A0042356