Solids contents

Lateral loading capacity

Design, dimensions

28
ø ≤ 5 mm (0.2 in)
≤75 Nm

Mechanical construction

For the dimensions, see the Product Configurator:
Search for product → click "Configuration" to the right of the product image → after
configuration click "CAD"
The following dimensions are rounded values. For this reason, they may deviate slightly from
the dimensions given on www.endress.com.
Device height
The device height is made up of the following components:
• Housing including cover
• Temperature spacer with gas-tight welded glass feedthrough (second line of defense)
• Compact version or pipe extension
• Process connection
The individual heights of the components can be found in the following sections:
• Calculate device height and add the individual heights of the components
• Take the installation clearance into consideration (space that is required to install the device)
 29
Components for calculating the device height
A
Housing including cover
B
Temperature spacer with gas-tight welded glass feedthrough → 2 lengths available depending on the process
temperature
C
Process connections
D
Compact version
E
Pipe extension
F
Installation clearance
Liquiphant FTL64
www.endress.com
Endress+Hauser
A0042418