Mounting

4.3

Manufacturer's address

Endress+Hauser SE+Co. KG
Hauptstraße 1
79689 Maulburg, Germany
4.4

Storage, transport

4.4.1
Storage conditions
• Permitted storage temperature: –40 to +70 °C (–40 to +158 °F)
• Use original packaging.
4.4.2
Transporting the product to the measuring point
Transport the device to the measuring point in the original packaging.
5
Mounting
5.1

Mounting requirements

• The device must be installed at a point in the process in such a way that ensures a constant
bulk density, as the bulk density directly affects the calculation of the water content. Where
necessary, a bypass should be created or structural measures may be needed at the place of
installation to ensure that the material flow, and therefore the bulk density, over the
measurement surface is constant.
• The measuring field of the device must be completely covered by material and the material
height must exceed the minimum layer of material covering on the measurement surface
(depends on the device type and moisture).
• The flow of material over the measurement surface must be continuous. With the software,
it is possible to automatically detect and bridge gaps in material flow in intervals of seconds.
• No material deposits or buildup may form on the measuring cell surface, as this would
falsify the readings.
Longer averaging times increase the stability of the measured value.
5.2

Mounting the device

The device can be installed with four screws (M5).
An appropriate cutout must be created at the place of installation for the measuring cell and
bores to secure it.