Moisture, temperature/conductivity
• Output 1: moisture in % (variable setting)
• Output 2: material temperature 0 to 100 °C (32 to 212 °F) and conductivity 0 to 20 mS/cm
with automatic window switching.
It is also possible to divide output 2 into two ranges to output both the conductivity and the
temperature, namely the 4 to 11 mA range for the temperature and the 12 to 20 mA range
for the conductivity. Output 2 automatically switches between these two windows every 5 s.
Output 1 can also be scaled at the factory or subsequently scaled as required (variably)
using the remote display (optionally available), e.g. 0 to 10 %, 0 to 20 % or 0 to 30 %
8.1.1
Possible settings
There are several possible settings for the analog outputs:
Analog outputs
Options:
• 0 to 20 mA
• 4 to 20 mA
The current output can also be set inversely for special controllers and applications.
• 20 to 0 mA
• 20 to 4 mA
Channels of the analog outputs
The analog outputs can be set differently to the following possible options:
Moisture, temperature
Output 1 for moisture, output 2 for material temperature.
Moisture, conductivity
Output 1 for moisture, output 2 for conductivity in the range from 0 to 20 mS/cm
(factory setting)
Moisture, temperature/conductivity
Output 1 for moisture, output 2 for material temperature and conductivity with
automatic window switching.
Moisture range
The moisture range and the temperature range at outputs 1 and 2 can be individually
configured.
The moisture range may not exceed 100 %.