MMP60 SONO GS
Moisture measurement
Solutions
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser MMP60 SONO GS

  • Page 1 Products Solutions Services BA01946M/00/EN/01.18 71418832 2018-10-29 Operating Instructions MMP60 SONO GS Moisture measurement...
  • Page 2 MMP60 SONO GS Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3: Table Of Contents

    Temperature compensation of internal SONO electronics ....... 27 16.1.5. Compensation of the temperature of the material being measured ....27 16.2. The analog outputs for outputting the measured values ......... 28 16.3. The SONO probe serial interface ................29 Endress+Hauser Page 3...
  • Page 4 MMP6 SONO GS1 16.3.1. Error output and error messages ................ 29 Setting the right operating mode for the probe ........... 30 Page 4 Endress+Hauser...
  • Page 5: Introduction

    Commissioning and maintenance via the serial interface of the moisture probe: on the PC using the SM-USB module, or alternatively using the SONO-VIEW display and operating module. • 2 × 0(4) to 20mA analog output for moisture and conductivity/temperature. Endress+Hauser Page 5...
  • Page 6: Documentation

    MMP6 SONO GS1 2. Documentation The following types of documentation are available in the Download area of the Endress+Hauser website (www.endress.com/downloads): For an overview of the Technical Documentation pertaining to the device, please refer to the following: • W@M Device Viewer (www.endress.com/deviceviewer): enter the serial number on the nameplate •...
  • Page 7: Basic Safety Instructions

    Due to the transfer of heat from the process and power dissipation of the electronics, the temperature of the electronics housing and the assemblies contained therein can increase to up to 80°C (176°F). The sensor may reach a temperature close to the medium temperature during operation. Endress+Hauser Page 7...
  • Page 8: Workplace Safety

    It meets the general safety requirements and legal requirements. 3.5.1. CE mark The measuring system meets the legal requirements of the applicable EC Directives. These are listed in the corresponding EC Declaration of Conformity along with the standards applied. Page 8 Endress+Hauser...
  • Page 9: Incoming Acceptance And Product Identification

    • Enter the serial number on the nameplate in W@M Device Viewer (www.endress.com/deviceviewer): all the information about the device is displayed. • Enter the serial number on the nameplate into the Endress+Hauser Operations App or scan the 2-D matrix code (QR code) on the nameplate with the Endress+Hauser Operations App: all the information about the device is displayed.
  • Page 10: Product Lifecycle

    Auto-correction, the probe recalibrates automatically in event of abrasion • No additional evaluation units are required. • Measured value display via optional SONO-VIEW operating and display module Maintenance • No maintenance is necessary • Technical experts available on demand at the manufacturer's facility Page 10 Endress+Hauser...
  • Page 11: Measuring Principle

    The modular TRIME technology enables special applications with very little effort and can be adapted to many applications due to the variable probe design. Endress+Hauser Page 11...
  • Page 12: Input

    Silo, conveyor belt 0% to 5% Max. 5mS/cm Ceramic mass Under the conveyor belt 0% to 30% Max. 12mS/cm Sand-lime Under the conveyor belt 0% to 30% Max. 12mS/cm Detergents Under the conveyor belt 0% to 30% Max. 12mS/cm Page 12 Endress+Hauser...
  • Page 13: Output

    SONO-VIEW operating and display module. Optionally, it is possible to connect the SONO probe to a PC via the SM-USB module to make calibration settings and other parameter settings in Windows with the SONO-CONFIG software (see the SONO-CONFIG software). Endress+Hauser Page 13...
  • Page 14: Electrical Connection

    Brown Brown IMP-Bus RT Gray/Pink Gray/Pink IMP-Bus COM Blue/Red Blue/Red 2nd Analog Positive (+) Pink Pink 2nd Analog Return Line (-) Gray Gray Shield Transparent Transparent (is grounded at the sensor. The installation must be properly grounded!) Page 14 Endress+Hauser...
  • Page 15 0 to 20mA current signal. The 500 Ohm shunt resistor should be fitted at the end of the line or at the input of the controller. The circuitry is illustrated in the diagram below. Endress+Hauser Page 15...
  • Page 16: Performance Characteristics

    2 x analog output 0(4) to 20mA Output 1: moisture in % (the measuring range can be individually set in the range from 0 to 100%) Output 2: conductivity (EC-TRIME) or optionally temperature, or optionally the standard deviation. Page 16 Endress+Hauser...
  • Page 17 SONO GS1 moisture probes are fitted with a rugged 10-pin MIL flange connector. Ready-made connecting cables are available in cable lengths 4m, 10m or 25m. A special version without a MIL connector and with an IP68 cable entry and a special cable can be ordered on request. Endress+Hauser Page 17...
  • Page 18: Operation And Connectivity To Sono Probes

    MMP6 SONO GS1 11. Operation and connectivity to SONO probes 11.1. Wiring diagram for connection to SONO-VIEW and the PLC Page 18 Endress+Hauser...
  • Page 19 SONO-VIEW allows users to view measured values and configure SONO probes. The moisture content determined and the conductivity / temperature can either be fed directly into a PLC via two analog outputs 0(4) to 20mA, or queried via the serial interface. Endress+Hauser Page 19...
  • Page 20: Sono-Gs1 Installation And Mechanical Construction

    MMP6 SONO GS1 12. SONO-GS1 installation and mechanical construction The SONO-GS1 probe can be installed directly in the floor of a container or in a screw conveyor. Page 20 Endress+Hauser...
  • Page 21: Installation Of The Sono-Gs1 Under A Conveyor Belt

    The thickness of the conveyor belt may not exceed 8mm. • The sliding plate must be individually fitted and secured depending on the conveyor belt. • The thickness of the conveyor belt must be taken into consideration with a basic calibration or a material calibration. Endress+Hauser Page 21...
  • Page 22: Installation Of The Sono-Gs1 In A Screw Conveyor

    It is recommended to use either operating mode CK for installations where there is interference from the screw, or operating mode CF for installations where part of the screw conveyor is cut out, see the chapter "Overview of the individual operating modes in different applications". Page 22 Endress+Hauser...
  • Page 23: Protection Of Mil Probe Connector Against Abrasion

    After the installation of the probe and the connection of the MIL connector, the heat-shrink tube can be shrunk onto the connector and cable with a hot air blower. The picture depicts a SONO VARIO Endress+Hauser Page 23...
  • Page 24: What To Do In The Event Of Suboptimal Material Flow

    In addition, in the case of non-homogeneous material flow it is possible to use the filter functions, with upper and lower limits, that are implemented in the SONO probe to filter out "wrong" measured values (see SONO-VIEW and SM-USB manuals). Additional installation instructions are documented in the "SONO Application Manual". Page 24 Endress+Hauser...
  • Page 25: Calibration Curves Cal1 To Cal15

    SONO-VIEW and SM-USB manual). SONO probes generally measure at a radar transit time of 60 picoseconds in air, and 1000 picoseconds in water. See the SM-USB and SONO-VIEW manuals for details on selecting the calibration curve, performing a calibration in the process and additional probe configuration options. Endress+Hauser Page 25...
  • Page 26 MMP6 SONO GS1 Page 26 Endress+Hauser...
  • Page 27: Special Functions

    SONO probes. If materials being measured, such as maize, show a very special temperat ure dependency of the DC, such as a temperature dependency only in very specific moisture ranges, it may be necessary to perform much more complex temperature compensation which involves a Endress+Hauser Page 27...
  • Page 28: The Analog Outputs For Outputting The Measured Values

    Analog output 1 for moisture, output 2 for material Moist, Temp/Conductivity temperature and EC-TRIME conductivity with automatic current window changeover. Analog output 1 for moisture, output 2 for standard Moist / MoistSTdDev deviation with moisture measurement (for use in fluidized bed dryers, for example). Page 28 Endress+Hauser...
  • Page 29: The Sono Probe Serial Interface

    SONO probes are very fault-tolerant, enabling interference-free operation. A prolonged EMC disturbance is detected during moisture measurement and output as an interference signal at the analog output with 21mA on channel1. Error messages can be queried via the serial interface. Endress+Hauser Page 29...
  • Page 30 SONO probes are supplied from the factory with the CH operating mode for applications in the construction industry and for many other applications. Six different operating modes are available in the C-Mode, depending on the application. See Manuals SD02332M SM-USB SD02333M SONO-VIEW Page 30 Endress+Hauser...
  • Page 32 *71418832* 71418832 www.addresses.endress.com...