Troubleshooting
Code
Description
P651
BAT Conv. SW1 OT
P652
BAT Conv. SW2 OT
P690
PCS Internal OT
P700
Slave MCU Comm.
P701
PMS Comm. Error
P702
BAT1 Comm. Error
P720
Slave MCU Error
P721
MCU Power Fault
P722
GD Desat
P723
GD Low Voltage
P724
Temp. Sensor
P740
ATS Error
P741
Initial Charge
P750
Grid Volt Sensor
P751
Grid Freq Sensor
P752
Safety Function
P753
Micom State Fail
P760
SRD Para Fault
P765
Relay Power Off
P900
SRD Para Warning
P910
Eeprom Warning
P925
PMS E-Stop

SE Box Error Code

Code
Description
S100
PCS version does not match
S101
BMS version does not match
S102
EEPROM device error
S200
Grid meter communication error
118
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Due to our policy of continuous product innovation, some specifications may change without notice.
Solution
Automatically restart after Converter top temp is
normal
Automatically restart after Converter bottom temp
is normal
Automatically restart after Inner temp is normal
Automatically restart after Communication is normal
Automatically restart after Communication is normal
Automatically restart after Communication is normal
Automatically restart after releasing fault
Automatically restart after MCU Control Power is
normal
Automatically restart after releasing fault
Automatically restart after releasing fault
Automatically restart after temp. sensor is normal
Automatically restart after ATS is normal
Automatically restart after releasing fault
Automatically restart after grid voltage sensing is
normal
Automatically restart after grid frequency sensing is
normal
Automatically restart after safety function operation
is normal
Automatically restart after MICOM state is normal
Automatically restart after releasing fault
Automatically restart after relay is normal
Automatically restart after releasing fault
Automatically restart after releasing fault
Automatically restart after releasing stop
Solution
Contact service center
Contact service center
Contact service center