Procedure
1. Remove the protective cover from the diaphragm of the remote seal. Use extreme
2. Place the appropriate gasket for the application on the remote seal.
3. Ensure that the SHP Cherry-Burrell seal is flush with the process connection.
4. Install clamp and tighten to manufacturer's specifications.
3.22
SLS dairy process connection–female thread
seal per DIN 11851
Figure 3-29: SLS Hygienic Dairy Process Connection Female Thread Seal per DIN
11851
3.22.1
Parts required for installation
The parts required to install the SLS dairy process connection seal will be defined here.
Prior to installation, you will need the following:
Gasket (end-user-supplied)
Wrench (optional, depending on clamp)
Verify the gasket material is appropriate for the application. Ensure to use an EHEDG
approved gasket if EHEDG conformance is needed.
3.22.2
Installation steps
Follow these steps to install the SLS dairy process connection seal:
Rosemount DP Level
caution during installation to ensure the diaphragm is not damaged.
WARNING
Failure to properly install the gasket may cause process leaks, which can result in
death or serious injury.
Installation