Daiichi Electronics SQLC-110L Instruction Manual page 63

Power line super multimeter
Hide thumbs Also See for SQLC-110L:
Table of Contents

Advertisement

Measurement
Measurement range /
item
Display specification
Harmonic 5th
Voltage 0.0 to 20.0% UV-VW
conversion
Current 0.0 to 100.0% U-V-W
content
Display:Integer, 5 digit.
Multiplier:Integral number times of 10.
Watt-hour
Possible to indicate it to 3 decimal place.
Electric power is integrated. (Power
receiving,Power transmission)
Display:Integer, 5 digit.
Multiplier:Integral number times of 10.
Possible to indicate it to 3 decimal place.
var-hour
Integrating reactive power of power
receiving. (LAG・LEAD)
Integrating reactive power of power
transmission. (LAG・LEAD)
18
Note(
) If this unit directly measures an inverter output of cycle control, SCR phase angle control or PWM control,
an error may increase due to its operation principle.
As for harmonic 5th conversion effective value and nth harmonic effective value, a display will be zero by
0.2% or less of the measurement range. And, analog output constitutes lower limit output.
At this time, a distortion factor, harmonic 5th conversion content rate, and nth harmonic content also become
0% (analog output is lower limit output). As for a distortion factor, harmonic 5th conversion effective
value / content, and nth harmonic effective value / content, fundamental wave effective value constitutes
zero by 3% or less of the measurement range.
Note(
19
) Analog output and pulse output are options.
The analog output of harmonic distortion factor and harmonic content is with respect to the current 0 to 100%
and voltage 0 to 20%, will be the upper limit output from the lower limit.
20
Note(
) At the case of one side swing setting of bar graph. Digital meter measures reverse power to -15% full
scale. (Instantaneous power)
21
Note(
) Active power, reactive power display digit.
A full scale display is below 4000:4 digits display. A full scale display is 4000 or more:3 digits display.
Example) 4800kW
22
Note(
) The maximum value (maximum demand current, others) minimum value can be checked in the maximum and the
minimum measurement mode.
Current
input
→ 4.80MW
40kvar → 40.0kvar
20kW
→ 20.00kW
Intrinsic error (
Analog output
Digital
Pulse output
display
±1.0%
±2.5%
±2.5%
±2.5%
Power factor 1
Power factor 1
:±2.0%
:±2.0%
Power factor
Power factor
0.5
0.5
:±2.5%
:±2.5%
Power factor 0
Power factor 0
:±2.5%
:±2.5%
Power factor
Power factor
0.87
0.87
:±2.5%
:±2.5%
Please refer to an appendix table for details.
62
18
)
Maximum
Minimum
measur-
measur-
ement
ement
19
(
)
SQLC-220-086
Note
Digital display is %
to 100% of content.
Conformity with normal
watt-hour meter.
Setting range of pulse
output unit
(kWh/pulse) is
referred to option-
specification.
Setting range of pulse
output unit
(kvarh/pulse) is
referred to option-
specification.