Daiichi Electronics SQLC-110L Instruction Manual page 27

Power line super multimeter
Hide thumbs Also See for SQLC-110L:
Table of Contents

Advertisement

Setting mode 2. Function table (1)
Setting
Function
No.
211
Voltage range
212
Current range
Current display
213
peculiar sensitivity
Active power
214
polarity
215
Active power range
216
Reactive power range
217
Power factor range
218
Frequency range
221A
AO1 output factor
(
10
)
222A
AO2 output factor
10
(
)
223A
AO3 output factor
10
(
)
224A
AO4 output factor
10
(
)
225A
Current output
10
(
)
peculiar sensitivity
226A
Active power output
10
(
)
peculiar sensitivity
Reactive power
227A
output peculiar
10
(
)
sensitivity
228A
Low input cut
10
(
)
241P
PO1 factor
10
(
)
242P
PO1 pulse unit
10
(
)
243P
PO2 factor
10
(
)
244P
PO2 pulse unit
10
(
)
251
External operation
10
(
)
input 1 function
252
External operation
(
10
)
input 2 function
10
Note(
) Setting item is not displayed in case there is no corresponding option.
11
Note(
) In 220V input, it becomes "220V".
12
Note(
) In 220V input, it becomes "40.0kW" and "20.00kvar".
13
Note(
) In 220V input, it becomes "0.1kWh/p".
Functional description
Set the voltage measurement range
(VT ratio).
Set the current measurement range
(CT ratio).
Set the full scale of current meter.
Set the swing display of active power
meter.
Set the full scale of active power
meter.
Set the full scale of reactive power
meter.
Set the full scale of power factor meter.
And, set this output range of analog
output.
Set the full scale of frequency meter.
And, set this output range of analog
output.
Set the output factor of AO1 (analog
output 1).
Set the output factor of AO2 (analog
output 2).
Set the output factor of AO3 (analog
output 3).
Set the output factor of AO4 (analog
output 4).
Set the analog output sensitivity
(% of output for input) of current.
Set the analog output sensitivity (% of
output for input) of active power.
Set the analog output sensitivity (% of
output for input) of reactive power.
Set the function which makes a lower
limit the output at the case of a
minute input (adequate to 0.5% or less)
in analog output.
Set the output factor of PO1 (pulse
output 1).
Set the output pulse unit of PO1
(pulse output 1).
Set the output factor of PO2 (pulse
output 2).
Set the output pulse unit of PO2
(pulse output 2).
Set the function of the external
operation input 1.
Set the function of the external
operation input 2.
Current
input
6600V (
100.0A
100.0A
One side swing
1200kW (
600kvar (
0.5 to 1 to 0.5
45.0 to 65.0Hz
A(V)
V(UV)
W
cosφ
100.0%
100.0%
50.0%
OFF (No operation)
Wh
10kWh/p (
Wh
10kWh/p (
Alarm reset
Maximum / Minimum
reset
26
Important
Default setting
setting
11
)
12
)
12
)
13
)
13
)
SQLC-220-086
Page
47 to
51
47 to
51
47 to
51
47 to
51
47 to
51
47 to
51
47 to
51
47 to
51
52
52
52
52
52,53
52,53
52,53
52,53
54
54
54
54
55
55