Daiichi Electronics SQLC-110L Instruction Manual page 51

Power line super multimeter
Hide thumbs Also See for SQLC-110L:
Table of Contents

Advertisement

◆ 216 Reactive power display intrinsic sensitivity
Set the full scale of reactive power meter.
The settable range is 30 to 115% of the reactive power range
(VT ratio x CT ratio in the attached table), and can be selected
from the [Power / reactive power display intrinsic sensitivity
(full scale) list].
Selection by + and - , set value is updated by SET .
<Caution> VT ratio:In case of 220V direct input.
Calculates by VT ratio=2.
CT ratio:In case of 1A input.
Calculates by CT ratio÷5.
Default setting:600kvar
<Note> The reactive power display is LEAD on
the left and LAG on the right.
There is no power polarity display.
(2 quadrant display)
Also, changing this setting does not
change the sensitivity of the analog
output. When changing the sensitivity
of analog output, set "227A Reactive
power output intrinsic sensitivity".
【Active power and Reactive power display intrinsic sensitivity (Full scale) list】 Unit:[W] or [var]
Full scale
Full scale
400
420
450
480
500
560
600
640
720
750
800
840
900
960
1000
1200
1400
1500
1600
1800
2000
2400
2500
2800
3000
3200
3600
Full scale
4.00k
40.0k
4.20k
42.0k
4.50k
45.0k
4.80k
48.0k
5.00k
50.0k
5.60k
56.0k
6.00k
60.0k
6.40k
64.0k
7.20k
72.0k
7.50k
75.0k
8.00k
80.0k
8.40k
84.0k
9.00k
90.0k
9.60k
96.0k
10.00k
100.0k
12.00k
120.0k
14.00k
140.0k
15.00k
150.0k
16.00k
160.0k
18.00k
180.0k
20.00k
200.0k
24.00k
240.0k
25.00k
250.0k
28.00k
280.0k
30.00k
300.0k
32.00k
320.0k
36.00k
360.0k
Current setting
Setting No.
Multimeter
LEAD
Current
CT
direction
Reactive
power
Image of reactive power display
Full scale
Full scale
400k
4.00M
420k
4.20M
450k
4.50M
480k
4.80M
500k
5.00M
560k
5.60M
600k
6.00M
640k
6.40M
720k
7.20M
750k
7.50M
800k
8.00M
840k
8.40M
900k
9.00M
960k
9.60M
1000k
10.00M
1200k
12.00M
1400k
14.00M
1500k
15.00M
1600k
16.00M
1800k
18.00M
2000k
20.00M
2400k
24.00M
2500k
25.00M
2800k
28.00M
3000k
30.00M
3200k
32.00M
3600k
36.00M
50
Full scale
Changing the display intrinsic
sensitivity changes the full scale of
the bar graph.
New setting
Reactive power display
intrinsic sensitivity
LAG
Full scale
40.0M
42.0M
45.0M
48.0M
50.0M
56.0M
60.0M
64.0M
72.0M
75.0M
80.0M
84.0M
90.0M
96.0M
100.0M
120.0M
140.0M
150.0M
160.0M
180.0M
200.0M
240.0M
250.0M
280.0M
300.0M
320.0M
360.0M
SQLC-220-086
Full scale
400M
420M
450M
480M
500M
560M
600M
640M
720M
750M
800M
840M
900M
960M
1000M

Advertisement

Table of Contents
loading

Table of Contents