BATTERY FUSE REPLACEMENT

The following procedure should be followed when replacing the battery fuse.
ο
Set CO M- 120C Main Power Switch to O FF.
ο
Remove all power sour ces fr om CO M- 120C.
ο
Loosen 4 scr ews on Batter y Access Panel.
ο
Remove Batter y Access Panel.
ο
Disconnect Positive (+) and Negative (-) Terminals from battery.
ο
Remove Batter y fr om cavity.
ο
Pull Batter y cable out of CO M- 120C until Batter y Fuseholder is exposed.
ο
Unscr ew Batter y Cable Fuseholder cap and r emove fuse.
ο
Replace fuse with 10 A, 32 V, Type F, AG C fuse.
ο
Feed Batter y Cable into Chassis.
ο
Install Batter y in cavity.
ο
Connect Positive (+) and Negative (-) Terminals to Battery. Install Battery Access
Panel.
NEGATIVE (-) TERMINAL
POSITIVE (+) TERMINAL
CO M- 120C Batter y and Batter y Cable
Page 4
BATTERY CABLE
BATTERY CABLE FUSE HOLDER
8707005