SECTION 6
OPTIONS
6-6-2

RECEIVE DATA CONFIGURATION SECTION

This section contains the par ameter s for setting the Receiver Por tion of the BER Meter .
Functions and par ameter s for the Receiver por tion of the BER Meter ar e as follows:
17. Receive Data Input
Displays selected Input for BER
Meter . Selections include RF
RECEIVER and AUDIO DATA IN.
Selecting RF RECEIVER means an
RF Car r ier is demodulated to r eceive
the Data Signal. Selecting AUDIO
DATA IN means Data Signal is
r eceived dir ectly thr ough the
AUDIO /DATA IN Connector .
The following items ar e displayed
only when RF RECEIVER is selected
as Receive Data Input ( 17) :
18. RF Field
Displays RF Receive Fr equency. Selections r ange fr om 0.0000 to
1000.0000 MHz.
19. Attenuation
Displays Input Attenuation. Selections ar e 0 or 30 dB.
20. IF Bandwidth
Displays IF Filter Bandwidth. Selections ar e 300 and 15 kHz.
21. Coupling
Displays Coupling Type for RF Receiver . Displayed only with FM selected for
Demod Type ( 26) . Selections ar e AC or DC.
22. Deviation Range
Displays FM Deviation Range. Displayed only with FM selected for Demod Type
( 26) . Selections ar e 10, 20, 50 and 100 kHz.
23. Bandpass Filter
Displays Bandpass Filter setting for demodulated signal. Selections include O FF
and C- MSG ( C- Message Weighted Filter ) .
High- Pass Filter /Low- Pass Filter combination and Bandpass Filter cannot be
active simultaneously.
Receive Data: RF RECEIVER
27
RF:
105.0000
Input:
ANT
Demod:
FM
Coupling:
AC
26
Deviation Range:
Data / Ber - Filter:
LPF: OFF
00607095
25
6- 6
17
18
19
Att:
30 dB
IF BW: 15 kHz
20
100 kHz
21
BPF: OFF
HPF: OFF
22
23
24