Registration Test - IFR COM-120C Operation Manual

Communications service monitor
Table of Contents

Advertisement

6-13-11

REGISTRATION TEST

The Registr ation Test simulates a Registr ation or der fr om the Cell Site and tests the
Mobile Phone's r esponse.
To per for m the Registr ation Test, pr ess F1 REG .
completed, r esults ar e displayed.
1. SCM
Displays 4
least
significant
Station Class
Mar k bits.
2. Power Class
Displays Power
Class of
Mobile Phone
under test.
3. Tr ansmission
State
Displays Tr ansmission State, Continuous or Discontinuous, of Mobile Phone under
test.
4. Bandwidth
Displays bandwidth of Mobile Phone under test. 20 MHz allows channels 1 to
666. 25 MHz allows channels 1 to 1023.
5. DCC
Displays Digital Color Code last r eceived by Mobile Phone under test.
6. ESN
Displays Electr onic Ser ial Number of Mobile Phone under test in Hexadecimal,
Decimal and O ctal.
7. MIN
Displays Mobile Identification Number of Mobile Phone under test.
Registration
Mobile Init
Cell Init
7
MIN:
316/522-4981
ESN:
HEX 8208A4C4
6
Dec 13000566468
Oct 20202122304
DCC:
2
5
REG
MOBILE
6- 63
After the Registr ation Tests ar e
AMPS Cellular
Manual Test
SCM: 0100
POWER CLASS 1
DISCONTINUOUS
BANDWIDTH: 20 MHz
CELL
SECTION 6
OPTIONS
1
2
3
4
RETURN
8717126