SECTION 6
OPTIONS

6-13-8 CELL INIT TEST

The Cell Init ( Cell Site Initiated) Test simulates a call fr om the Cell Site. The following
pr ocedur e per for ms the Cell Init Test:
o
With cur sor on Cell Init, pr ess F2 ENABLED. Pr ess F3 START to star t test.
o
" Paging Mobile" , " Page Answer ed" and " Ringing Mobile" messages appear as Test
Set per for ms test.
o
" Answer Phone" pr ompt appear s. Answer call placed to Mobile Phone.
o
" Measur ing Fr equency" message appear s indicating Maintenance O r der is sent to
the Mobile Phone for measur ing Signal Tone fr equency.
o
If Maintenance O r der does not fail, " Pr ess Flash Hook" pr ompt appear s. Pr ess
Flash Hook on Mobile Phone. " Hangup Phone" pr ompt appear s. Hanging up Mobile
Phone completes Cell Init Test.
A Power Level Test is also per for med with the Cell Init Test. Refer to par agr aph
6- 13- 3B for Power Level Test infor mation. After the Cell Init Test is finished, pr ess
F2. Results to page thr ough the Cell Init Test r esults.