6-13-7 MOBILE INIT TEST

The Mobile Init ( Initiated) Test r equir es a call to be initiated fr om the Mobile Phone.
The following pr ocedur e per for ms the Mobile Init ( Initiated) Test:
o
With cur sor on Mobile Init, pr ess F2 ENABLED=. Pr ess F3 START to star t test.
o
" Place Call" pr ompt appear s. Place call using Mobile Phone under test.
o
" Enter Digits" pr ompt appear s. Enter up to 16 digits using Mobile Phone to test
DTMF tr ansmission. Pr essing F1 Cont continues Mobile Init Test with or without
digits enter ed.
o
" Pr ess Flash Hook" pr ompt appear s. Send Flash Hook signal using Mobile Phone.
Pr essing F1 Cont continues Mobile Init Test without testing Flash Hook message.
o
" Measur ing Fr equency" message appear s indicating Maintenance O r der is sent to
the Mobile Phone for measur ing Signal Tone fr equency.
o
" Pr ess Flash Hook" pr ompt appear s. Send Flash Hook signal using Mobile Phone.
" Hangup Phone" pr ompt appear s. Hang up Mobile Phone or pr ess F5 Release for
r elease or der to be sent to Mobile Phone. When " Hangup Phone" pr ompt
disappear s, Mobile Init Test is finished.
o
Power Level Test is per for med with the Mobile Init Test. After testing is finished,
pr ess F2 Results to page thr ough r esults. Mobile Init Test r esults r esemble the