Data Generator/Bit Error Rate (Ber) Meter (Option 07) - IFR COM-120C Operation Manual

Communications service monitor
Table of Contents

Advertisement

SECTION 6
OPTIONS
6-6

DATA GENERATOR/BIT ERROR RATE (BER) METER (OPTION 07)

To access the BER Meter , pr ess SPCL TEST MO DE Key and select the Bit Er r or Rate.
The BER Meter is designed for Baseband, RF G ener ate, RF Receive or Duplex Mode.
The complexity of the BER Meter is best descr ibed in four separ ate sections.
BER Meter G ener al O per ation Scr een
BER Meter Configur ation Section
Receive Data Configur ation Section
Send Data Configur ation Section
1. BER Meter Configur ation Section
Contains configur ation data for signal.
2. Peak Reading
Displays highest Bit Er r or Rate for cur r ent test.
3. Loop Count
Displays number of times Data has been sent.
BIT ERROR RATE METER
Send Data: RF GENERATOR
RF:
10.0000
Level:
-30.0
7
Output:
T/R
Type:
OFF
Receive Data: RF RECEIVER
RF:
105.0000
Input:
ANT
Demod:
FM
IF BW: 15 kHz
Coupling:
AC
Deviation Range:
100 kHz
Aud/Data Filters:
BPF: OFF
6
LPF: OFF
HPF: OFF
Bit Error Rate:
5
BER Meter O per ation Scr een
Run Mode:
Data Rate:
Size:
Data Pattern:
Data Polarity:
Peak Hold:
Upper Limit:
Att:
30 dB
Alarm:
Peak High:
0 EXP - 3
Loop Count:
Deviation:
6- 2
LOOP
10
1200 BPS
100000 Bits
1
FIXED
NORMAL
ON
OFF
OFF
2
0 EXP - 6
0
3
- + -
--- kHz
00616015
4

Advertisement

Table of Contents
loading

Related Products for IFR COM-120C

Table of Contents