Pepperl+Fuchs IUH-F190-V1-FR2-12 Manual page 62

Uhf read/write head for identcontrol
Table of Contents

Advertisement

IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Command:
Response:
The following settings are possible:
<Timeout>: "0" ... "100" (x 100 ms, timeout in 100 ms steps)
<Baud>: "1,200" , "2,400" , "4,800" , "9,600" , "19,200", "38,400"
The default values are a timeout of "0" and a baud rate of "38,400".
Reset RS
This command interrupts all currently running commands. The device settings are reloaded
from the non-volatile memory.
Command:
Response:
The command must be executed after a configure interface CI or define a function DF, so that
the changes become active.
Configuration Commands
See chapter 6.6 and see chapter 6.5
The device address must be specified.
Read/Write Commands
See chapter 6.4.
Examples:
Single Read Words SR
The read/write head makes one attempt to read <WordNum> 32-bit words from the address
<WordAddr>.
Command:
Response:
The result of the command must be retrieved with the command GD.
Get Data GD
This command retrieves the data from the read station. Each data record is transferred only
once.
Data is only available for read commands. There is no data component for write commands.
Command:
Response:
Repeat Response RR
This command triggers a repeat of the last telegram received on 'GD'.
Command:
Response:
62
CI <DeviceNo> <Timeout>, <Baud> <CHCK> <ETX>
<Status> <DeviceNo> <CHCK> <ETX>
RS <DeviceNo> <CHCK> <ETX>
"2" <DeviceNo> <CHCK> <ETX>
SR <DeviceNo> <WordAddr> <WordNum> <CHCK> <ETX>
<Status> <DeviceNo> <CHCK> <ETX>
GD <DeviceNo> <CHCK> <ETX>
<Status> <DeviceNo> <ExecCounter>{<Data>}<CHCK> <ETX>
RR <DeviceNo><CHCK> <ETX>
<Status> <DeviceNo> <ExecCounter> {<Data>} <CHCK> <ETX>

Advertisement

Table of Contents
loading