Countries Of Use; European Union; Argentina - Pepperl+Fuchs IUH-F190-V1-FR2-12 Manual

Uhf read/write head for identcontrol
Table of Contents

Advertisement

IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.3

Countries of Use

Note
Transmission License
A country-specific transmission license is required to operate the read/write head. In the
European Union, the manufacturer's declaration of conformity constitutes an adequate license.
All currently valid transmission licenses can be found in the datasheet for the respective
read/write head at www.pepperl-fuchs.com.
Note
Country Identifier
All read/write heads operate within their maximum frequency range with the appropriate
settings for the relevant country. The country-specific settings are configured during production
and cannot be subsequently modified.
Note
If you wish to use the read/write head in a country not included in this chapter, make sure the
relevant values for the read/write head are consistent with the local conditions before use.
The frequency access procedure used is part of the country-specific settings.
Frequency Access Method
In many countries, including the USA and China, a frequency hopping spread spectrum is
used. See chapter 3.2.7. The number and position of the frequencies is fixed and cannot
be changed by the user. All channels are used.
A programmable frequency list is used in other countries, including the European Union,
Singapore, Vietnam, and India. You can compile this frequency list from a specified set of
channels. Four channels are specified in the European Union as appropriate for dense
reader mode in accordance with EN 302208. See chapter 3.2.6. With this setting, you can
configure one, multiple, or all four channels.
3.3.1

European Union

In the European Union, the use of RFID in the UHF range is regulated by EN 302208.
UHF frequency range: 865 MHz ... 868 MHz
Radiated power: 3 mW ... 1000 W
Channel bandwidth: 200 kHz
Channel spacing: 600 kHz
Frequency access method: programmable frequency list
Number of predefined channels: 4
Programmable channels: 4, 7, 10, 13
Center frequencies: 865.7 MHz, 866.3 MHz, 866.9 MHz, 867.5 MHz
Up to 4 channels can be parameterized and used in sequence.
Default: dense reader mode with channel 4, 10, 7, 13. See chapter 3.2.6.
3.3.2

Argentina

The regulations for the UHF frequency range in Argentina are the same as the regulations for
the UHF frequency range in the USA. See chapter 3.3.20.
; Default = 50 mW
ERP
ERP
17