IUH-F190-V1-*, IUT-F190-R4-V1*
Installation
4.3.1

Room Orientation

The alignment of the read/write tag antennae in relation to the antennae of the read/write head
influences the detection range of the system. Make sure the antennae are aligned parallel to
each other.
Read/write head
1
Tag
2
4.3.2

Minimum Distances

When positioning the read/write head, please observe the minimum distances. The lateral dis-
tance between the read/write head and metals or liquids should be at least 50 cm. The distance
between the read/write head and the ground should be at least 50 cm.
Figure 4.2
32
Optimum alignment of the tag
1
2
Good communication between the read/write head
and tag
Poor alignment of the tag
1
2
Insufficient communication between the read/write
head and tag
metal support