IUH-F190-V1-*, IUT-F190-R4-V1*
Product Description
3.5
Technical Data
General Data
Operating frequency
Light power
Electrical Data
Current consumption
Power consumption
Power supply
Rated operating voltage
Surge protection
1. Only IUH-F190-*
Ambient Conditions
Ambient temperature
Storage temperature
Degree of pollution
Classification
Mechanical Data
Degree of protection
Connection
Material Housing
Material Mounting base
Weight
3.6
Indicators and Operating Elements
The read/write head has 3 LEDs, which are green/blue/yellow. The various indicators denote:
•
Green LED: Power on
•
Blue LED: Transmission mode
•
Yellow LED: Read/write operation successful
3.7
Connection
Caution!
Cable specifications
The maximum permissible temperature of the connection cable must be at least +80 °C.
The minimum diameter of the connection cable must be 22 AWG or 0.34 mm².
Country-specific, see chapter 3.3
Country-specific, see chapter 3.3
450 mA
9 W
1
from IDENTControl
20 ... 30 V
, ripple 10 % SS, limited power source
DC
(EN60950) for IUT-F190*
Category 2
-20 ... 70 °C (-4 ... 158 °F) (operation with transmission
pauses, adjustable)
-20 ... 60 °C (-4 ... 140 °F) (continuous transmission
operation)
-40 ... 85 °C (-40 ... 185 °F)
2
Environmental condition A (controlled environment)
IP67
Connector M12 x 1
PA 6
Aluminum, die cast
860 g
25