In Case Of Repair: Use In Combination With Split Bearing; With Split Seals - Schaeffler SES Series Mounting Manual

Split plummer block housings
Table of Contents

Advertisement

Shaft (not stepped)
Stepped shaft
Shaft ring with grub screws
Housing ring with O ring
Mounting the outer taconite seal
Final mounting
of Taconite seals ETC
End face of housing ring
End face of shaft ring
Setting the position of the shaft ring
of the Taconite seal
In case of repair:
Dismounting and mounting

with split seals

Application in combination
with a split bearing
Schaeffler Technologies
Spacer sleeve
2.
3.
V ring
Figure 26
1
The outer seal is mounted.
Continue with section Inserting the shaft and bearing into
the housing, page 20.
Position the shaft ring of the Taconite seal axially such that
the end faces of the shaft ring and the housing are flush.
Fully screw tighten the shaft ring on the shaft using the grub
screws provided.
Grub screw
Shaft ring
Figure 27
The mounting of the seal on the first side is complete.
Repeat the process for the seal on the other side.
Continue with section Checking the tightening torques, page 22.
In case of repair, split seals are fitted. If unsplit seals were fitted on
initial assembly, these are replaced by split seals when the repair
work is carried out.
In case of repair, the work involved in mounting can be significantly
reduced if the unsplit bearing originally fitted is replaced by a split
bearing and split seals are fitted at the same time.
1.
4
3.
5
6
3
4
6
4
5
1.
2.
6
3
5
4
2
1
2
4
MON 92