3. Technical data

3.1 Mechanical data

Maximum capacity [l/h] *
Maximum capacity with anti-cavitation 75 % [l/h] *
Maximum capacity with anti-cavitation 50 % [l/h] *
Maximum capacity with anti-cavitation 25 % [l/h] *
Maximum pressure [bar]
Maximum stroke rate per minute [strokes/min.]
Maximum suction lift during operation [m]
Maximum suction lift when priming with wet valves [m]
Maximum viscosity with spring-loaded valves [mPa s] **
Maximum viscosity without spring-loaded valves [mPa s] **
Diaphragm diameter [mm]
Liquid temperature [°C]
Ambient temperature [°C]
Accuracy of repeatability
Sound pressure level [dB(A)]
*
Irrespective of counter pressure
**
Maximum suction lift 1 metre

3.2 Electrical data

Supply voltage [VAC]
Maximum current consumption [A]
Maximum power consumption P
Frequency [Hz]
Enclosure class
Installation category
Pollution degree
Insulation class
Supply cable
10
at 100 V
at 230 V
[W]
1
DME 60
DME 150
DME 375
60
150
45
112
33.4
83.5
16.1
40.4
10
4
160
6
1.5
3000 [mPa s] at 50 % capacity
200
79
106
0 to 50
0 to 45
± 1 %
< 70
DME 60
DME 150
DME 375
1 × 100-240 V
1.25
0.67
67.1
50/60
IP65
II
2
B
1.5 m H05RN-F with plug
DME 940
376
940
282
705
210
525
101
252
10
4
124
173
DME 940
2.4
1.0
240