5. Functions

5.1 Control panel

1
2
3
100%
4
5
6
7
8
Pos. Description
LCD display.
1
See section Menu
Navigation/settings.
2
See section Menu
Green indicator light.
3
See section Alarm output and indicator lights
Maximum capacity (priming).
4
See section Priming/venting of pump
Red indicator light.
5
See section Alarm output and indicator lights
M12 connection analog/pulse/leakage input.
6
See sections Pulse, Analog, Diaphragm
leakage sensor
Cable for Profibus control.
7
See section Fieldbus communication
Connection alarm relay.
8
See section Alarm output and indicator lights
9
Power supply
M12 connection level control.
10
See section Level control
Pos. Description
M12 connection stop dosing.
11
See section Start/stop of pump
On/off button.
12
See section Menu
14
Navigation/settings.
13
See section Menu
13
Menu.
14
See section Menu
12
Related information
11
5.2 Start/stop of pump
5.3 Priming/venting of pump
5.4 Level control
10
5.5 Diaphragm leakage sensor
5.7 Fieldbus communication
5.8 Menu
5.11 Pulse
5.12 Analog
9

5.2 Start/stop of pump

The pump can be started/stopped in two different
ways:
Locally on the pump control panel.
By means of an external on/off switch. See
section Connection overview.
Related information
4.6 Connection overview

5.3 Priming/venting of pump

The pump control panel incorporates a
Press this button if the maximum pump capacity is
required over a short period, e.g. during start-up.
When the button is released, the pump automatically
returns to the previous operating mode.
During priming/venting, it is recommended to let the
pump run without a counter pressure or to open the
vent valve.
Note: When the buttons
simultaneously, the pump can be set to run for a
specific number of seconds at maximum capacity.
The remaining number of seconds will appear in the
display. The maximum value is 300 seconds.
100%
button.
100%
and
are pressed