Technical Data; Operating Conditions; Mechanical Data; Electrical Data - Grundfos SCALA2 Installation And Operating Instructions Manual

Table of Contents

Advertisement

15. Technical data

15.1 Operating conditions

Temperature
Max. ambient temperature
1 × 208-230 V, 60 Hz:
1 × 115 V, 60 Hz:
1 × 200-240 V, 50/60 Hz:
Max. liquid temperature
Pressure
Max. system pressure
Max. inlet pressure
Other operating data
Max. head
IP rating
Pumped liquid
Noise level
3)
44 dB(A) is measured in a typical application at duty point Q
3
= 1 m
/h and H = 19 m in accordance with ISO 3745.

15.2 Mechanical data

Pipe connections are R 1" or NPT 1".
[°C (°F)]
45 (113)
45 (113)
55 (131)
45 (113)
[bar (psi)]
[MPa]
10 (145)
1
6 (87)
0.6
45 m (147 ft)
X4D (outdoor installation)
Clean water
3)
< 44 dB(A)

15.3 Electrical data

Supply
Frequency
voltage [V]
[Hz]
1 × 200-240
50/60
1 × 208-230
60
1 × 115
60
Supply
Frequency
voltage [V]
[Hz]
1 × 200-240
50/60
1 × 208-230
60
1 × 115
60
Stand-by
P1
I
[A]
power
max.
[W]
[W]
2
2
2.8
550
2
2
2.8
550
2
4.9
550
2
Plug
Schuko
Schuko EAC
Schuko SNI
AUS
UK
ARG
Chile
Thailand
India
None
No plug CN
No plug AR1
No plug AR2
NEMA 6-15P
IEC, type B, NEMA 5-15P
Japan
None
31

Advertisement

Table of Contents
loading