2. General description

The Grundfos DME dosing pump is a self-priming
diaphragm pump.
The pump consists of:
a cabinet incorporating the drive unit and
electronics,
a dosing head with back plate, diaphragm,
valves, connections and vent valve,
a control panel incorporating display and
buttons. The control panel is fitted either to the
front or to the side of the cabinet.
The motor is controlled in such a way that the dosing
gets as even and constant as possible, irrespective of
the capacity range in which the pump is operating.
This is carried out as follows:
The speed of the suction stroke is kept constant and
the stroke relatively short, irrespective of the capacity.
Contrary to conventional pumps, which generate the
dosing stroke as a short pulse, the duration of the
dosing stroke will be as long as possible. Thus, an
even dosing without peak values is ensured. As the
pump is always dosing at full stroke length, it ensures
the same high accuracy and suction capability,
irrespective of the capacity, which is infinitely variable
in the ratio of 1:800.
The pump features an LCD display and a user-
friendly control panel which gives access to the pump
functions.

2.1 Applications

The pump is suitable for liquid, non-abrasive, non-
flammable and non-combustible media strictly in
accordance with the instructions in these installation
and operating instructions.
Areas of application (among others)
drinking water treatment
wastewater treatment
cooling water treatment
washing systems
process water treatment
chemical industry.

2.2 Improper operating methods

The operational safety of the pump is only
guaranteed if it is used in accordance with section
Applications.
Warning
Other applications or the operation of
pumps in ambient and operating
conditions, which are not approved, are
considered improper and are not
permitted. Grundfos cannot be held liable
for any damage resulting from incorrect
use.
8
Warning
The pump must be equipped with a
diaphragm leakage detection when used
for crystallising media.
Warning
The pump is NOT approved for operation
in potentially explosive areas!
Warning
A sunscreen is required for outdoor
installation!
Related information
2.1 Applications

2.3 Identification

2.3.1 Type key
The type key is used to identify the precise pump and
is not used for configuration purposes.
Type
DME60-10AR-PP/E/C-F-311F
Nominal dosing capacity [l/h]
DME60-10AR-PP/E/C-F-311F
60
150
375
940
Max. pressure [bar]
DME60-10AR-PP/E/C-F-311F
4
10
Control variant
DME60-10AR-PP/E/C-F-311F
AR
Standard
AP
Standard + Profibus