4.1 Signal Description (Input Signal Order)

For safety, the servo motor drive‟s input signal is deal with the signal of motor stop firstly.
Item
Description
01
Most priority operation signal
02
Priority operation signal
03
Signal to limit the torque
04
Signal to stop the servo motor
05
Signal to make the motor rotatable
06
Signal to decide the home position
Signals regardless of the operation
07
of the servo motor
If using the free-run command, the moving element of lifting mechanical system may drop. If it is
unnecessary, please do not equip with it.
The response time of external input terminal and output terminal is 1 [ms].
If the settings of reducing deviation or zero signals etc are performed, it may not be identified by the host
controller PLC (Generally, the scanned time of the PLC is dozens of [ms].
Corresponding signal (function NO.)
・Free-run command (54)
・Servo ON (1)
・Forced stop (10)
・Torque limit 0 (19)
・Torque limit 1 (20)
・+OT (7)
・- OT (8)
・Command pulse inhibit (26)
・Pause (31)
・Positioning cancel (32)
・Deviation clear (50)
・Forward rotation (2)
・Reverse rotation (3)
・Auto-start(4)
・Homing (5)
・Homing LS (6)
・Interrupt input (49)
・Position preset (16)
・Alarm reset (11)
・Edit permission command (55)