List Of Descriptions For Functional Parameters - Savch SDA2 Series User Manual

Servo system
Table of Contents

Advertisement

3.2 List Of Descriptions For Functional Parameters

In the parameter editing mode and positioning data editing mode, the check and change of the setting value
is available.
Mode
Control status
display mode
Monitoring mode
△Feedback position
△Command position
△Position deviation
○Command pulse frequency
△Command cumulative
○LS-Z pulse
○Input signal
○Output signal
Remarks:△: With a triangle label, the data has upper/middle/lower segments when viewed.
○: With a round label, the data has upper/lower sections when viewed.
Sub-mode
Action mode
Feedback speed
Command speed
Command torque
Motor current
Peak torque
Effective torque
Feedback cumulative
pulse
pulse
Load inertia ratio
DC link voltage(max)
DC link voltage(min)
VREF input voltage
TREF input voltage
OL thermal value
Sub-mode selection
Cn-01
dP-01
dP-02
dP-03
dP-04
dP-05
dP-06
dP-07
dP-08
dP-09
dP-10
dP-11
dP-12
dP-13
dP-14
dP-15
dP-16
dP-17
dP-18
dP-19
dP-20
dP-21
38
Display and setting
example
-
PoF
3000
3000
300
000.0
300
300
99
09
00
1
00
00
104
300.0
300
300
10.00
10.00
ii
ii
001
Unit
rpm
rpm
%
A
%
%
unit
unit
unit
kHz
pulse
pulse
pulse
V
V
V
V
%

Hide quick links:

Advertisement

Table of Contents
loading