2.5 Basic Wring Diagram

2.5.1
Servo Motor & Drive Wiring Diagram
No-Fuse Breaker (NFB)
To prevent the large instant
current received by the
power-on, power-off or the
short circuit and damage
the drive.
Magnetic Contactor (MC)
When fault alarm was
received,the servo drive
could be used together to
output alarm signal (ALARM)
and control the contactor
(MC),and stop the servo
drive power.
External retrogradation
resistor
( optional )
Installation Notes:
1. Check the R, S, T and the L1C ,L2C power and connecting wire.
2. Check the servo motor output U, V, W terminal phase wires (Unable to run when the connection is wrong).
3. External connected regeneration resistor is the selective spare, adopt according to the actual needs.
4. When fault or emergent stop was received, cut the power of magnetic contactor (MC) through ALARM output
to stop the power of drive.
5. * indicates being developed.
Power Supply
Three phase AC 200 ~ 230V
Three phase AC 380 ~ 460V
Grounding terminal
Servo motor Power cable
SDA2 Servo Drive
Servo Drive
14
*Connect to the computer software
Servo drive cascade connection
STO Safety circuit interface
( optional )
*Connect to grating ruler
( optional )
Encoder cable