2.7 Basic Wiring Diagram Under Different Control Modes

2.7.1 Position control mode
Notes 1: When the external power are adopted, do not connect the COM with IP24,external power supply 24V
connected to COM.
Notes 2:The EI input terminal that is marked △ indicates that the default function is not defined, user can set the
required function according to the parameter of Chapter 6.
Notes 3: The diode installation direction could not be connected by the wrong way, max working voltage 24V,
max output current 50mA; the current value of external relay ring should be lower than 80mA. When the
current value is greater than 80mA, the power should be supplied externally.