16. ERROR MESSAGE TABLE
CMT Operation Mode
MISMATCH SPEC.
BAD TAPE OR CMT
TIME OUT ERROR
LON System Mode
Error message
COMMUNI.
ERROR
SEQUENCE
ERROR
SEQUENCE #
ERROR
MASTER BUSY
BM NOT RESET
TEXT ERROR ##
Get user manuals:
See SafeManuals.com
Message
Mismatch of the model type.
Mismatch of the base unit.
Mismatch of the VERSION.
Mismatch of the TRANS-
MITTING DATA.
Mismatch of the scale
capacity.
Parity error
Framing error
Overrun error
Data error
Two or More Hardware error
Time out error
1. The power of the master or backup
master scale is not turned ON.
They are not connected with each
other or in off-line state.
2. LON cable is broken.
The power was not turned OFF and
ON again after setting ID #.
Text data number is incorrect.
Registration job is performed on a
satellite scale while reset job is per-
formed on the master scale.
The backup master does not have
same PLU with the mater scale.
1. Error text is found.
02: Sequence No. error
05: LRC error
08: Text error
09: Command error
2. The master scale differs from other
scale in ROM version.
M: Master scale
Cause
Press the CLEAR key.
Press the CLEAR key.
Press the CLEAR key.
Cause
1. Turn the power of the master
2. Call your authorized service
Turn the power switch OFF and
ON again.
Call your authorized service
representative.
1. Quit reset job on the master
2. Quit registration job on the
Down load PLU from the master
to the backup master scale.
Then run the reset operation
again.
Call the TOSHIBA TEC autho-
rized service representative.
BM: Backup master scale
16-3
16. ERROR MESSAGE TABLE
Solution
Solution
or backup master scale ON.
Connect them with each other
or turn the scale in-line.
representative.
scale.
satellite scale.
S: Satellite scale
B BM/S