14. OPERATING PROCEDURES
NOTES: 1. To print NET WT. data. from the FIX mode, load a label which has an area to print a NET WT
2. The quantity sold number and price data in NET WT. statement operation will be accumulated
3. The position of the decimal point is adjustable and a comma or period is selectable by the
4. Weight data is shifted to the left.
5. Weight data exceeding 480 oz results in an error.
6. Unit price calculation system
7. When the unit price is less than $0.01/lb or either the weight or price is 0, the unit price will
8. Multiplication registration of NET WT statement
Get user manuals:
See SafeManuals.com
Statement.
in the memory. No weight data will be accumulated.
initial setting.
(Step 1) Weight data is calculated from royal lb into decimal lb.
(Round off the data to two decimal places.)
ex.) 21 oz → 1.3125 lb → round → 1.31 lb
(Step 2) Price is divided by the value obtained above.
(Round off the data to two decimal places.)
1.5$/1.31 lb = 1.145 → round → $1.15/lb
ex.)
not be printed.
The maximum quantity, of a commodity is 99.
In the following cases, an error occurs when pressing the PRT/* key to issue the label.
(1) Quantity = 0
(2) Price x quantity > max. price
Weight x pieces > max. tare (30 lb scale: 480 oz, 15 Kg scale: 9.995 Kg)
(Sample label)
14.5 ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)
This data is printed.
14-10