Cable diameter that is calculated according to device capacity and cable length,
residual current device and fuse amper values can be seen at the following table.
Power
Phase&Voltage
(kW)
10
12
16
18
20
24
30
36
40
48
6
10
12
16
18
Cable sections at this table are calculated for maximum 10 m. Consult your
authorised service for more than 10 m cable length.
Current Drawn
(V)
(A)
3~400 V 50 Hz Devices
3~400
3*15,2
3~400
3*18,2
3~400
3*24,3
3~400
3*27,3
3~400
3*30,4
3~400
3*36,4
3~400
3*45,5
3~400
3*54,6
3~400
3*60,7
3~400
3*72,8
1~220 V 50 Hz Devices
1~220
27,3
1~220
45,6
1~220
54,6
1~220
72,8
1~220
81,9
Fuse&Residual
Current Device (A)
3*20
3*20
3*25
3*32
3*40
3*50
3*63
3*63
3*63
3*80
32
50
63
80
100
23
Cable Sections
(mm)
5*2,5
5*2,5
5*4
5*4
5*6
5*6
5*10
5*10
5*16
5*16
3*4
3*6
3*10
3*16
3*16