Summary of Contents for DAXOM UKDAX-80Y10BT

  • Page 2: Safety Warnings

    To Daxom User In order to perform device’s function properly and for your safety follow the instructions mentioned in the user manual of the device during the mounting and the usage of the device. In case of an unauthorized mounting and maintenance, the device will be void from warranty cover.
  • Page 3  After you unpack the device, be sure that content is in good position and complete otherwise contact with the sales agency that you have purchased the device.  Safety valve outlet must be connected to suitable discharge system. All responsibilities are belong to user in case of any damage that occurs because of any intervention to safety valve.
  • Page 4 2. SUGGESTIONS FOR ECONOMICALLY USED  Adjust ambient temperature according to your need. Increasing 1 degree of ambient temperature increases your energy consumption about %6.  Having homogeneous heating at parts according to intended use that is placed at the heating place, increases saving. ...
  • Page 5: Device Configuration

    3. DEVICE CONFIGURATION Wall Type products code explanations are as in the following. Ground type boiler product codes explanations are as in the following Products codes explanations of boiler without pump are as in the following.
  • Page 6 3.1. Wall Type Boiler With Tank...
  • Page 8 3.2. Floor Type Boiler With Tank 3.2.1. Floor Type 80 Liter Boiler With Tank...
  • Page 10 3.2.2. Floor Type 120 Liter Boiler With Tank...
  • Page 12 3.3. Wall Type Electric Boiler With External Tank...
  • Page 14: Technical Informations

    4. TECHNICAL INFORMATIONS 4.1. Wall Type Boiler With Tank Technical Specifications Boiler Weight Without Dimensions Model Power (kW) Capacity (l) Water (Kg) H*W*D (mm) 3~400 V 50 Hz Wall Type Electric Boiler With Tank UKDAX-10EBT 770*560*390 UKDAX-12EBT 770*560*390 UKDAX-16EBT 770*560*390 UKDAX-18EBT 770*560*390 UKDAX-20EBT...
  • Page 15 4.2. Floor Type Boiler With Tank Technical Specifications Power Boiler Weight Without Dimensions Model (kW) Capacity (l) Water (Kg) H*W*D (mm) 3~400 V 50 Hz Electric Boiler With Tank UKDAX-80Y10BT 836*600*590 UKDAX-80Y12BT 836*600*590 UKDAX-80Y16BT 836*600*590 UKDAX-80Y18BT 836*600*590 UKDAX-80Y20BT 836*600*590 UKDAX-80Y24BT 836*600*590...
  • Page 16 4.3. Wall Type Electric Boiler With External Tank Technical Specifications Power Expansion Weight Without Dimensions Model (kW) Tank (l) Water (Kg) H*W*D (mm) 3~400 V 50 Hz Electric Boiler With Tank UKDAX-10HBT 23,5 700*400*220 UKDAX-12HBT 23,5 700*400*220 UKDAX-16HBT 700*400*220 UKDAX-18HBT 700*400*220 UKDAX-20HBT 700*400*220...
  • Page 17: Device Installation

    5. DEVICE INSTALLATION Device installation must be done by authorised personnel. 5.1. Installation Conditions and Safety Warnings Obey minimum distance that is anticipated for installation in order to reach the device for making maintenance and repair. For Correct Device Installation; ...
  • Page 18  Device installation place must be far way from blockers, obstruction parts and bulges during repairing and maintenance. There must be sufficient space around the device for maintenance and repair.  Electric connection of the device must be made with suitable cable, fuse and residual current device and grounding absolutely must be made.
  • Page 20 5.3. Floor Type Device Installation Installation wall of the device must be as durable as carrying the full weight of the device. Before the plumbing connections are made, it must be completely balanced and the space in the mounting feet must be taken.
  • Page 21 5.4. Connection Of Heating Systen and Water Installation Heating system must be drawn with suitable diameter pipe for providing enough circulation of heating water. Choosing Radiator pipes smaller than it is needed, fitting constriction or blockage can inability circulation of heating. Connections that are made to device must be easy removable when it is needed.
  • Page 22  Discharge the accumulated air inside radiators by opening air relief cock placed in side of radiators and close when water starts to flow.  When the accumalted air inside radiators discharge it can be decrease at heating system water pressure. Make sure that heating system water pressure is between 1 and 1,5 bar.
  • Page 23 Cable diameter that is calculated according to device capacity and cable length, residual current device and fuse amper values can be seen at the following table. Power Phase&Voltage Current Drawn Fuse&Residual Cable Sections (kW) Current Device (A) (mm) 3~400 V 50 Hz Devices 3~400 3*15,2 3*20...
  • Page 24 6. DEVICE OPERATION AND USAGE 6.1. LED Display Operating Condition and settings of the device can be follow from LED panel. Radiator / floor heating indicator Days Of Week Time Programming. Can be made 7 pcs time programming Hour Capacity Indicator Ready to operation Indicator Hot Water Heating Indicator Radiator Heating Indicator...
  • Page 25 6.2. Control Buttons Control of the device is done with buttons placed under the LED Display. On / Off Menu exit / Changing Temperature increase / Hour and day setting Temperature decrease / Back Timer program On / Off 6.3. Device Operation First operation of the device must be absolutely done by authorized service.
  • Page 26  Hold 2-3 min to button for device ON Device keeps last settings in its memory before OFF. When it is ON again, starts to operate with same settings.  When operation of the device is set as boiler heating before OFF position if boiler temperature is lower than set temperature, device operates for boiler heating symbols are seen with “shower”, expressions...
  • Page 27 If boiler temperature is equal or over the set temperature , device operates for radiator symbols are seen with “heating” and “shower”, expression. heating.  When operation of the device is radiator heating before OFF, device operates for is seen with “heating” expression after pump operates about radiator heating.
  • Page 28  Hold button 5-6 seconds. Days start to blink.  Days are set by pressing with one second intervals to buttons.  Press button hour blinks.
  • Page 29  By pressing one second interval hour is set between 0 and 23  Press button, minute blinks.  By pressing button one second interval min set between 0 and 60.
  • Page 30  By pressing button or if not pressing any button for a 10 sec, exit from setting menu by saving settings. 6.4.2. Radiator Temperature Setting While symbols are seen at LED Display, (when device is operating for radiato system) radiator heating setting can be made between 35 C and 80 C by buttons.
  • Page 31 immediately, radiator heating starts after pump operates for a while for temperature balance. 6.4.3. DHW Temperature Setting Boiler temperature setting ; symbols are seen at LED Display. When symbol blinks (when device operates for boiler heating) setting can be made between 30 C ile 65 C by pressing...
  • Page 32 While radiator heating is operating, for setting temperature of tap water,it is needed to change operation mode of the device as tap water heating. At the end of this process, device must be taken to previous operation mode.( Check 6.4.8) After 2 sec later setting completed, device operation temperature and “Water Temp”...
  • Page 33  Press the button one second interval until is seen. Temperature difference start to blink.  ΔT temperature difference is set with buttons  Exit setting menu by pressing...
  • Page 34 6.4.5. Room Thermostad Setting It is possible to command device with room thermostad. In this way, device operates according to temperature of environment of room thermostad place. Room thermostad connection must be done by authorized service while the device is activated.
  • Page 35  Press button one second interval until is seen. Heating mode choosing indicator blinks.  “0” is chosen with symbols for floor heating mode. “1” is chosen for radiator heating.
  • Page 36 For floor heating systems because of heating mode is set from inside device by authorized service, in this menu “0” set can not be changed.  Exit setting menu by pressing button. Definitely temperature must not set over 55 C for floor heating systems. In case of setting our companies is not responsible from damages or accidents that may occur.
  • Page 37  Press one second interval until is seen.  With buttons, device capacity can be set as P1, P2 or P3. Indicator lights change according to chosen capacity.
  • Page 38  Exit menu by pressing button. 6.4.8. Setting Operation Mode Device can operate as 3 different operation modes.  Radiator Operation Mode: Device only heats radiators. Tap water heat does not occur.  Boyler Çalışma Modu: Cihaz sadece boyleri ısıtır. Şofben ya da yaz konumu olarak da adlandırılabilir.
  • Page 39  Press button one second interval until “heating” and / or “shower” blink.  With button preferred mode is chosen. If “heating” is chosen device only operates for radiator heating.
  • Page 40 If “shower” is chosen device operates for boiler heating. If “heating” and “shower” are chosen at the same time device operate for both radiator and boiler heating.  Exit menu by pressing button.
  • Page 41 6.4.9. Time Program Setting The device can be programmed daily and weekly for radiator heating. With 7 different time programs, the start and end times of the program, the operating temperature of the device during program and the ΔT temperature difference can be adjusted. If the programming has been made and activated, the device will not be heated during periods of time that are not programmed.
  • Page 42  By pressing buttons timing program is chosen between 1 and 7.  Press button  With buttons timing program is “ON” position. If it stays at “OFF” position, can not be entered to timing program.
  • Page 43  By pressing button week day / days are chosen. With buttons, intended week day or days can be chosen. Week days are group as in the following.  All days can be chosen (SUN. MON. TUES. WED. THUR. FRİ. SAT.) ...
  • Page 44  Weekdays (MON. TUES. WED. THUR. FRI.)  Days can be chosen one by one  Press button, program start hour blinks.
  • Page 45  With buttons, program start hour is determined.  Press button. Program start minute blink.  Program minute is determined with...
  • Page 46  Press button. Program finish hour blink.  With buttons program finish hour is determined  Press button. Program finish min blink.
  • Page 47  With buttons program finish minute is determined.  Press button. Temperature indicator blink.  Operation temperature of intendent program is chosen with buttons.
  • Page 48  Press button. symbol and exit / return temperature difference adjustment indicator blink.  Intendent ΔT (exit /return temperature difference) at selected program is chosen with buttons.  Press . Other intetendent time program is chosen and repeat starting from 3 step.
  • Page 49  Setting all time programs are not necessary. You can set time programs between 1 and 7 as much as you want. Because of unadjusted programs remain “OFF” position, they will not be active.  After programming is finished, when it is pressed to button or not pressing any button with 10 seconds can exit from setting menu by saving settings.
  • Page 50 By activating electric supply, device will be protected by following steps  Freezing Prevention Function: If temperature of water inside device reduces under 5 C, device operates fpr a while by getting involved pump an heating. Buring antifrost time is seen at LED display. ...
  • Page 51: Electrical Diagram

    7. ELECTRICAL DIAGRAM 7.1. Three Ohase Devices...
  • Page 52 7.2. Single Phase Devices...
  • Page 53: Repair And Service

    8. REPAIR AND SERVICE During guarantee time of product we provide Free of Charge Service to users against defect of related materials and production about device. When you meet with problem while using, please contact with our after sales service department. Repairing and maintenance of the device by unauthorizedperson will make the device out of warranty.
  • Page 54 PROBLEM SOLUTION WAYS REASON  No electric  Residual current device or  Control if there is electric Fuse is off or not ● ●  Connection problem of  Control residual current power card with control device and fuse ...