Değerli Daxom Kullanıcısı, In order to perform device’s function properly and for your safety follow the instructions mentioned in the user manual of the device during the mounting and the usage of the device. In case of an unauthorized mounting and maintenance, the device will be void from warranty cover.
Page 3
Hydraulic system operation pressure must be between 1 and 2 bars therefore it must not exceed 3 bars. In case of need reduce water pressure of heater circuit from discharge valve of installment. Mg-Anot bar which is inside enameled boiler, provides durability against to corrosion.
Page 4
2. SUGGESTIONS FOR ECONOMICALLY USED Adjust ambient temperature according to your need. Increasing 1 degree of ambient temperature increases your energy consumption about %6. Having homogeneous heating at parts according to intended use that is placed at the heating place, increases saving. ...
Wall Type Boiler With Tank Technical Informations Weight Without Water Boiler Model Power (kW) (Kg) Volume(l) 3~400 V 50 Hz Electrical Boiler With Tank UKDAX-10EBT UKDAX-12EBT UKDAX-16EBT UKDAX-18EBT UKDAX-20EBT UKDAX-24EBT 1~220 V 50 Hz Electrical Boiler With Tank UKDAX-6 EBM UKDAX-10 EBM UKDAX-12 EBM...
Page 8
Floor Type Boiler With Tank Technical Informations Weight Boiler Dimensions Power Without Model Capacity Y*G*D (kW) Water (mm) (kg) 3~400 V 50 Hz Electrical Boiler With Tank UKDAX-80Y10BT 836*600*590 UKDAX-80Y12BT 836*600*590 UKDAX-80Y16BT 836*600*590 UKDAX-80Y18BT 836*600*590 UKDAX-80Y20BT 836*600*590 UKDAX-80Y24BT 836*600*590 UKDAX-120Y10BT 1152*600*590 UKDAX-120Y12BT...
Page 9
Waşş Type External Boiler With Tank Technical Informations Power Dimensions Weight Expansion Model Tankı (l) (kW) Y*G*D (mm) (Kg) 3~400 V 50 Hz Electrical Boiler With External Tank UKDAX-10HBT 700*400*220 23,5 UKDAX-12HBT 700*400*220 23,5 UKDAX-16HBT 700*400*220 25,0 UKDAX-18HBT 700*400*220 25,0 UKDAX-20HBT 700*400*220...
Page 16
Wall Type Boiler With Tank Kapasite 10-24 700 400 220 58 122 277 342 65 200 123 100 200 30-48 700 450 320 83 147 302 367 75 225 148 100 225 *ölçüler mm cinsindendir.
Page 17
Plumbing Connection Diagram Of External Boiler With Tank:...
Page 18
5.1. Installation Conditions and Safety Warnings Obey minimum distance that is anticipated for installation in order to reach the device for making maintenance and repair. For Correct Device Installation; Installation must not be made on the cooker or similar cooking devices. ...
Page 19
When heating system increases over 3 bar, water disposal starts from safety valve. For Ukdax-xxHBT ve Ukdax-xxHBM models , 50 K NTC boiler sensor must be installed. When boiler pressure increases over 8 bar, drainage starts from safety valve. ( For Ukdax-xxEBM ve Ukdax-xxEBT )Boiler max operating pressure is 6 bar.
Page 20
5.2. Wall Installation Of Device Installation wall of the device must be as durable as carrying the weight of the device. Fix the fixing plugs by drilling the appropriate diameter and number of mounting holes in the place chosen in accordance with the above conditions. Screw the upper hanger plate of the device tightly.
Page 21
5.2.1.Connection Of Heating System and Water Installation Heating system must be drawn with suitable diameter pipe for providing enough circulation of heating water. Choosing Radiator pipes smaller than it is needed, fitting constriction or blockage can inability circulation of heating. Connections that are made to device must be easy removable when it is needed.
Page 22
5.2.1.2. Filling Of Heating System Filling process is done with blue colour filling tap under the device. This process must be done by implementing following instructions. Be sure that inlet tap of boiler is open. Open the filling tap. ...
Page 23
5.2.2. Electric Connection Electrical installation must be done by authorized person according to device capacity and with suitable diameter cable. Electric of device must have suitable specification for for cut off device power and residual current device that has amper value and fuse separately.
Page 25
6. DEVICE OPERTION AND USAGE 6.1. LCD Display Operating Condition and settings of the device can be follow from LCD panel. Radiator Heating Indicator Floor Heating Indicator Days Of Week Time Programming. Can be made 7 pcs time programming Hour Capacity Indicator Ready to operation Indicator Hot Water Heating Indicator...
Page 26
6.2. Control Buttons Control of the device is done with buttons placed under the LCD Display. 6.3. Operation Of Device First operation of the device must be absolutely done by authorized service. Our company is not responsible from damages and accidents which can be occured with intervention to device by unauthorized people.
Page 27
Hold 2-3 min to button for device ON .Device keeps last settings in its memory before OFF. When it is ON again, starts to operate with same settings. When operation off device is set as boiler and radiator heating before OFF position if boiler temperature is lower than set temperature, device symbols are seen with “heating”...
Page 28
If boiler temperature is equal or over the set temperature , device operates for symbols are seen with “heating” and “shower”, radiator heating. expression. When operation of the device is set as boiler heating before OFF position if boiler temperature is lower than set temperature, device operates for boiler symbols are seen with “shower”, expressions heating symbol...
Page 29
Warning beep is heard after process of pressing knob. For long time pressing knobs (forexample 2-3 seconds), before hearing warning warning beep, it does not mean pressing knob. 6.4. Operation Parameter Setting 6.4.1. Day and Hour Setting Switch Off the device.
Page 30
Days are set by pressing with one second intervals to buttons. button hour blinks. Press By pressing one second interval hour is set between 0 and 23...
Page 31
button , minute blinks. Press By pressing button one second interval min set between 0 and By pressing button or if not pressing any button for a 10 sec , exit from setting menu by saving settings. ...
Page 32
6.4.2. Radiator and Temperature Setting While symbols are seen at LCD Display, (when device is operating for C and 80 C by radiato system) radiator heating setting can be made between buttons. While radiator heating setting is made, “Water Temp” pressing expression fizzle out, setting temperature value starts to blink.
Page 33
Boiler temperature setting ; symbols are seen at LCD Display. When symbol blinks. (when device operates for boiler heating ) setting can be made between 30 C ile 65 C by pressing...
Page 34
If operation mode is set as boiler heating, it is possible to change boiler temperature at standby mode. While radiator heating is operating, for setting temperature of boiler ,it is needed to change operation mode of the device as boiler heating. At the end of this process, device must be taken to previous operation mode.
Page 35
After device heats the boiler, it operates for radiator heating. Boiler heating starts again when decreases 7C from set temperature.
Page 36
6.4.4. Temperature Difference Setting Tempereature difference between Heating exit and Heating return of device can be set. While the device is in normal operation mode, Enter setting menu by pressing 2-3 seconds. Press the button one second interval until is seen.
Page 37
ΔT temperature difference is set with buttons. Exit setting menu by pressing 6.4.5. Room Thermostad Setting It is possible to command device with room thermostad. In this way, device operates according to temperature of environment of room thermostad place. Room thermostad temperature must be done by authorized service while first operation of device is making.
Page 38
6.4.6. Operation Mode Setting Device can be set according to floor heating (low temperature) or radiator heating system. In this way, overheating is prevented especially for floor heating systems. While the device is operating at floor heating mode max 55 degrees, it can be set max 80 C at radiator heating mode.
Page 39
0” is chosen with symbols for floor heating mode. ...
Page 40
“1” is chosen for radiator heating For floor heating systems because of heating mode is set from inside device by authorized service, in this menu “0” set can not be changed. Exit setting menu by pressing button.
Page 41
Device can operate with 3 different capacities. P1 mean is 1/3 capacity, P2 mean is 2/3 capacity, P3 mean is full capacity. Forexample if the device is 24kw, P1: 8 KW, P2:16kw, P3:24 KW. While device operates regularly; Enter setting menu by pressing button 2-3 seconds.
Page 42
Exit menu by pressing button. 6.4.8. Operation Mode Setting Device can operate 3 different operation mode. Radiator Operating Mode: Device only makes radiator heating. boiler heating does not occur.
Page 43
Boiler Operation Mode: Device only heats the boiler. This mode can also named as heater or summer mode. Radiator and Boiler Operation Mode.: Device makes both radiator heating and boiler heating. Priority is always for boiler heating. While radiator heating is ...
Page 44
button preferred mode is chosen. If “heating” is With chosen device only operates for radiator heating. If shower” is chosen device operates for boiler heating. If “heating” and “shower” are chosen at the same time device operate for both radiator and boiler heating.
Page 45
button. Exit setting menu by pressing 6.4.9. Time Programing Setting The device can be programmed daily and weekly for radiator heating. With 7 different time programs, the start and end times of the program, the operating temperature of the device during program and the ΔT temperature difference can be adjusted.
Page 46
button one second interval until “Timing Time Phase” is seen. Press Timing program blink. By pressing buttons timing program is chosen between 1 and 7. Press button.
Page 47
buttons timing program is “ON” position. If it stays at With “OFF” position, can not be entered to timing program. button week day / days are chosen. By pressing With buttons, intended week day or days can be chosen. Week days are group as in the following.
Page 48
Weekends (SUN. SAT.) Weekdays (MON. TUES. WED. THUR. FRI.) Days can be chosen one by one...
Page 49
button , program start hour blinks. Press With buttons, program start hour is determined. Press button. Program start minute blink.
Page 50
With buttons, program start minute is determined. Press button. Program finish hour blink. With buttons program finish hour is determined...
Page 51
button. Program finish min blink. Press With buttons program finish minute is determined. Press button. Temperature indicator blink. ...
Page 52
Operation temperature of intendent program is chosen with buttons. button. Press symbol and exit / return temperature difference adjustment indicator blink. Intendent ΔT (exit /return temperature difference )at selected program is chosen with buttons...
Page 53
. Other intetendent time program is chosen and repeat starting from Press step. Setting all time programs are not necessary. You can set time programs between 1 and 7 as much as you want. Because of unadjusted programs remain ...
Page 54
6.5. MAKE THE DEVICE OFF 6.5.1. Temporary OFF For short time OFF periods, provide the device OFF by pressing button 2 or 3 seconds. By activating electric supply, device will be protected by following steps Freezing Prevention Function : If temperature of water inside device reduces under 5C, device operates fpr a while by getting involved pump an heating.
Page 55
Anti – Blockade Function: Pump and 3 way valve inside the device start to operate for a short time once every 18 hrs. 6.5.2. Long Term OFF If you do not operate the device for a long time, make the circuit breaker OFF after pressing button 2or 3 seconds.
8. REPAIR AND SERVICE During guarantee time of product we provide Free of Charge Service to users against defect of related materials and production about device. When you meet with problem while using, please contact with our after sales service department. Repairing and maintenance of the device by unauthorizedperson will make the device out of warranty.
Page 58
Pipe is blocked or valve is Control if tis closed valve or not at heating closed installation and clean silt trap. Pump damage Flowmeter damage Call the authorized service.
Page 59
PROBLEM SOLUTION WAYS REASON No Electric Residual Current Device or Control if there is electric Fuse is Off or not. ● ● Connection problem of Control residual current power card with control device and fuse pannel card Call authorised service ...
Page 60