DAXOM THERMOCAR 16B Installation And User Manual

Dc caravan condensing gas boiler +electric

Advertisement

Quick Links

1

Advertisement

Table of Contents
loading

Summary of Contents for DAXOM THERMOCAR 16B

  • Page 2: Safety Warnings

    To DAXOM User In order to perform product function properly and for your safety follow the instructions mentioned in the user manual of the product during the mounting and the usage of the product. In case of an unauthorized mounting and maintenance, the product will be void from warranty cover.
  • Page 3: Boiler Configuration

    2. BOILER CONFIGURATION...
  • Page 4: Technical Informations

    3. TECHNICAL INFORMATIONS Device Model THERMOCAR 16B Gas Type LPG (G30/G31) Gas Inlet Pressure (mbar) Boiler Volume (I) Usage Boiler Volume (l) Heat Power (kW) Instant Hot Water Supply (∆t=20°C) (l/min)* Max Operation Temperature ( Electrical Connection (V) DC 12 Electrical Power Wıth Gas Heating (W)
  • Page 5 ➢ Necessary preventions must be taken for fresh air inlet pipe and discharge gas pipe for any obstacle outside caravan. ➢ Fresh air inlet pipe and discharge gas pipe must be near or close to fuel tank. ➢ There must be sufficient space at product installation place for maintenance and repairing ➢...
  • Page 6 Fix the fresh air inlet and discharge gas outlet connections to their place under the product by wrapping with heat resistant leakage proof metarial (preferably teflon tape). Tighten the connections solidly for not loose because of factors such as vibration. Place the product to it’s place by taking out pipes from opening holes inside the vehicle to outside.
  • Page 7 4.7. LCD Control Pannel Connection Electric connection must not be done before LCD control pannel is connected. The cable supplied with products has boiler connection socket on one end and numbered cables for LCD control pannel connection on other end. Boiler connection socket is fixed to it’s place on the boiler and fasten by tightening connection part.
  • Page 8 pannel from each other, pull up the control pannel by keeping the cover steady. Screw the cover from installation holes to suitable place inside vehicle. Fix the LCD pannel to it’s place again. Be sure that, connections of LCD control pannel are correct. Wrong connction can cause damage to devices.
  • Page 9: Product Usage

    5. PRODUCT USAGE 5.1. Control Pannel 5.2. Product Operation Our company is not responsible from damages and accidents in case of intervention of unauthorised person to product. Be sure that used gas type for product is same with determined in product label. Before operation of the product, suitability of all connections such as pipe, gas, mechanic and electrical must be contolled.Boiler must be filled completely and air of boiler must be discharged.
  • Page 10 5.3. Heating Choose Long term electric usage can be cause of accumulator discharge. This product is designed as function of heating water with both gas and electric. Both of heating system can not be operated at the same time. Requested fuel type for heating water can be chosen with switch on the pannel.
  • Page 11 ➢ Time program can be activated or pasivated with button. Appearing symbol at display shows that product is in mannual using and time program is passive. Appearing symbol shows that time program is active. 5.4.2. Setting Boiler Temperature Boiler temperature can be set betwwen 5 C and 65 C by pressing buttons...
  • Page 12 ➢ It is passed to another step by Wi-Fi connection and entering wifi pass word. ➢ While LCD pannel is OFF position, Press button until Wi-Fi symbol blink. ➢ It is passed to another step by pressing “Confirm the indicator is blinking rapidly”...
  • Page 13 ➢ Application home screen will be opened. All settings that is made on LCD pannel and more than this can be made from there. ➢ LCD pannel must be connected to Wi-Fi network for controlling by smart phone. 5.4.5. Controlled By Smart Phone For controling of LCD Pannel from smart phone, LCD pannel must be connected to Wi-Fi network that set up is made.
  • Page 14 5.5. Turn Off Device TURN OFF gas valve, electrical fuse and water inlet / outlet valve of product respectively. 5.6. The Precautions to be Taken ➢ Make sure the used gas type is the same with the one stated in the brand plate. The use of inappropriate type of gas may lead to accident.
  • Page 15: Maintenance And Service

    ➢ If you suspect that there is gas leakage except from pipe and pipe connections consult to your service agency. ➢ Make urgently change old or cracked pipes by authorized person after controlling gas pipes regularly. ➢ When unusual burning sound is heard in water, stop using the water heater and consult to our service agency.
  • Page 16 6.1. Cathodic Protection It is aimed to maximize the lifetime of product with cathodic protection. Cathodic protection is done with magnesium anode rods. Magnesium anode dissolves with the help of electrolysis in the tank, adheres to the needed points on the inner surface of the boiler and extend the life of the tank.
  • Page 17: Troubleshooting

    7. TROUBLE SHOOTING PROBLEM SOLUTION WAYS CAUSE ● No Energy Check the electricity fuse ● Gas valve is not ON Turn on gas valve or perform gas load ● Gas valve semi ON Turn On gas valve completely ● Air in the gas pipe Gas Turn on the gas valve completely ●...

Table of Contents