7748934 04-2008
Acknowledge message
1 Push the knob on the control panel to ackowledge
the alarm. The buzzer becomes silent.
2 Read the alarm or message in the pop-up.
3 Push the knob on the control panel again and the
pop-up disappears.
The alarm has to be acknowledged before the engine
can be started. Larmet måste kvitteras innan det går
att starta motorn.
Faults list
Is a fault registered the display shows Faults in the
EVC menu along with the number of faults.
Push the knob on the control panel to open the menue.
Turn the knob to see all faults registred.
The popup toggles between cause of fault and tasks
to perform.
Erasing faults in faults list
Acknowledged faults that has been stored automati-
cally erased every time the starter key is turned to the
stop position (S).
Stop the engine and check that the ignition key(s)
is(are) in position 0 in all control positions.
When system voltage is switched on again, the diag-
nostic function checks whether there are faults in the
EVC system. If this is the case, new fault pop-ups are
shown. Faults which have been attended to or have
disappeared are automatically erased.
Faults which have not been attended to must be
acknowledged every time the system voltage is
switched on.
Fault Handling